Editing a message
A36951-C.doc
65/236
REMINDER
New algorithm or print speed settings cannot be made on
messages that have already been created.
The content of the message has to be deleted first if you want
to change these parameter settings.
ʄ
Forward margin
Enter a forward margin value (in millimeters).
This parameter represents the space between the point where the object is detected and
the point where the message starts to be printed if the printed message starts from the first
character.
ʄ
Return margin
Enter a return margin value (in millimeters).
This parameter represents the space between the point where the object is detected and
the point where the message starts to be printed if the printed message starts from the
final character.
ʄ
Interval
Enter an interval value (in millimeters).
This parameter represents the space between two print operations in repetitive set-off
mode (
Set off
field set to REPETITIVE) or if "
Printing repetition
" is active.
ʄ
Top filter
Enter a time value (in
ȝ
s).
This parameter is the minimum time value that the object detection signal has to reach to
be taken into account by the printer. You can increase this time value if you have noticed
that messages have been printed at the wrong time.
ʄ
Set off
To determine how printing is to be set off.
Options:
Ƒ
MANUAL OBJECT or MANUAL AUTO: If you want to perform manual print tests.
. MANUAL OBJECT: Printing is triggered when you press the spacebar on your
keyboard. Printing is performed every time the spacebar is pressed.
. MANUAL AUTO: Printing is triggered when you press the spacebar and is repeated
until you press the spacebar again.
This means that you can print out the same message automatically several times
between each time you press the spacebar manually.
Summary of Contents for Markem Imaje 9040
Page 1: ......
Page 10: ...A36951 C doc 11 236 Général ...
Page 11: ...Général A36951 C doc 12 236 ...
Page 17: ...A36951 C doc 18 236 ...
Page 18: ...Description of the printer ...
Page 19: ...Description of the printer ...
Page 27: ...A36951 C doc 28 236 ...
Page 28: ...A36951 C doc 29 236 Description of operator interface ...
Page 29: ...Description of operator interface A36951 C doc 30 236 ...
Page 42: ...A36951 C doc 43 236 Daily operation ...
Page 43: ...Daily operation A36951 C doc 44 236 ...
Page 56: ...A36951 C doc 57 236 Editing a message ...
Page 57: ...Editing a message ...
Page 110: ...A36951 C doc 111 236 Servicing 9040 9040 IP65 9040S ...
Page 111: ...Servicing 9040 9040 IP65 9040S A36951 C doc 112 236 ...
Page 124: ...A36951 C doc 125 236 Servicing 9040 Contrast ...
Page 125: ...Servicing 9040 Contrast A36951 C doc 126 236 ...
Page 135: ...A36951 C doc 136 236 ...
Page 136: ...A36951 C doc 137 236 Maintenance ...
Page 137: ...Maintenance A36951 C doc 138 236 ...
Page 167: ...A36951 C doc 168 236 ...
Page 168: ...Alarms and faults ...
Page 169: ...Alarms and faults ...
Page 182: ...A36951 C doc 183 236 Installation and configuration ...
Page 183: ...Installation and configuration A36951 C doc 184 236 ...
Page 194: ...A36951 C doc 195 236 External communications ...
Page 195: ...External communications A36951 C doc 196 236 ...
Page 213: ...A36951 C doc 214 236 ...
Page 214: ... C Technical Specifications ...
Page 215: ...Technical Specifications C ...
Page 226: ...A36951 C doc 227 236 Consumables ...
Page 227: ...Consumables A36951 C doc 228 236 ...
Page 233: ...A36951 C doc 234 236 ...