background image

Part Number: M2051-EU, Rev. 1

Issue Date: V

Configuration Manual

MagLink LX4

M2051-EU

Revision: 1

Summary of Contents for MagLink LX4

Page 1: ...Part Number M2051 EU Rev 1 Issue Date V Configuration Manual MagLink LX4 M2051 EU Revision 1 ...

Page 2: ...oGauge is a part of Dover Fueling Solutions Contact START ITALIANA S r l Via Pola 6 20813 Bovisio Masciago MB Italy Tel 39 0362 1581465 Fax 39 0362 1581464 Copyright Information 2020 Dover Fueling Solutions All rights reserved DOVER the DOVER D Design DOVER FUELING SOLUTIONS and other trademarks referenced herein are trademarks of Delaware Capital Formation Inc Dover Corporation Dover Fueling Solu...

Page 3: ...1 1 Site Info 19 6 1 2 System 20 6 1 3 Protocols 22 6 1 4 Tank Group 23 6 1 5 Shifts 24 6 1 6 Fairbanks 25 6 1 7 SMTP 26 6 1 8 Site Mapping for Reconciliation Autocalibration mode only 26 6 1 8 1 Map Dispensers and Nozzles to Tanks 27 6 1 9 IFSF 28 6 1 10 DIP Switches 29 6 2 Notifications Menu 29 6 2 1 Contacts 29 6 2 2 Notifications 30 6 3 Tank Setup Menu 31 6 3 1 Settings 31 6 3 2 Thresholds 33 ...

Page 4: ... On Off 40 7 2 Discriminating sensors 41 7 3 Wireless 42 Section 8 Tank Status 44 Section 9 Tank Group Status 46 Section 10 Reports Menu 47 10 1 History 47 10 2 Tank Alarms 49 10 3 Sensor Alarms 49 10 4 Delivery 50 10 5 Leak Tests 51 10 6 Sales 52 10 7 Shifts 52 10 8 Reconciliation 53 Section 11 Maintenance 56 11 1 Timezone 56 11 2 Network Configuration 56 11 3 Utility 57 M2051 EU Rev 1 Dover Fuel...

Page 5: ...11 4 Console Settings 57 Section 12 Change Password 58 Section 13 Logout 59 Section 14 Guest Account 60 Section 15 Technical Support 61 M2051 EU Rev 1 Dover Fueling Solutions Page 5 ...

Page 6: ...vements and or changes in the product and or associated programs Start Italiana S r l is not liable for damages of any kind including those resulting in the document including typographical errors Making copies citing quotes or other reproductions of all or part of this document is permitted only after written consent of Start Italiana S r l Patents protect trademark or name Copyright 2019 Start I...

Page 7: ...service provider or manufacturer The manufacturer is not liable for injury and or damage to persons and or property and or pets caused by the failure to obey safety instructions All approved personnel must know all safety requirements in this manual the configuration manual and the user manual Refer directly to an approved service provider or manufacturer for questions about the operation of the e...

Page 8: ...onsole in the field as shown in the M2052 EU MagLink LX4 User Manual WARNING This device must not be discarded with household waste This device is labeled in accordance with European Directive 2012 19 UE concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE This guideline gives the methods for the return and recycling of used electronic devices as appl...

Page 9: ...e units of measurement contained in this manual refer to a specified selection by the user Refer to System on page 20 for more information on how to set units of measure M2051 EU Rev 1 Dover Fueling Solutions Page 9 ...

Page 10: ...could result in death or serious injury CAUTION Indicates a possibly hazardous situation that if not prevented could result in minor or moderate injury NOTICE Indicates important information not related to hazards A condition that if not prevented can result in property damage SAFETY INSTRUCTIONS Indicates instructions and procedures related to safety or gives the location of safety equipment 3 2 ...

Page 11: ...efore in the manual that is important to show again TIP A step or procedure that is recommended to make another step or procedure easier INFORMATION This panel shows references to more information in other sources M2051 EU Rev 1 Dover Fueling Solutions Page 11 ...

Page 12: ...ndard RJ45 as an option try an RJ45 Crossover cable Connect an RJ45 cable from your laptop Ethernet port to the Ethernet port on the bottom panel of the console Navigate to Control Panel All Control Panel Items Network and Sharing Center on your laptop 1 Click Change adapter settings in the left side panel M2051 EU Rev 1 Dover Fueling Solutions Page 12 ...

Page 13: ...click Local Area Connections 3 Select Properties from the menu 4 Select to highlight Internet Protocol version 4 IPv4 on the list in the pop up 5 Click Properties M2051 EU Rev 1 Dover Fueling Solutions Page 13 ...

Page 14: ... lower to connect to the console a Click the button next to Use the following IP address b Enter the IP address 10 90 10 92 c Enter the Subnet mask 255 255 255 0 7 Click OK Your laptop is now set up to communicate directly with your MagLink LX4 console Enter the IP address into your browser to connect M2051 EU Rev 1 Dover Fueling Solutions Page 14 ...

Page 15: ... Russian Spanish Chinese Simplified Chinese Traditional French Polish Serbian Cyrillicand Latin Turkish Croatian German Portuguese Slovakian Ukrainian Arabic Hindi Push the Enter button The Login page will come into view 1 Select a User type from the drop down There are three 3 types of Users n Guest Can only see Tank Status Sensor Status and Reports measures deliveries leakages sudden loss A Gues...

Page 16: ...el that are not approved See Change Password on page 58 for information TIP As you type your password only neutral bullet characters will show e g Select the eye icon to show the password characters as you type 3 Push the LOGIN button to log in to the console with the selected user type 4 If you did not select the applicable language in the Home screen you can push the LANGUAGE button to go back t...

Page 17: ...ispensers X TCP IP addressconfiguration DNS X Utilityoperations Backup restore Clean historicaldata Historicalreadings alarms reconciliation shift reports Touch screen calibration of the console Restarting the console Restarting the operating system of the console X Reconciliation if enabled X Shift report with scheduling X IFSF module configuration X Sensorscurrent status X X Autocalibration Anal...

Page 18: ...limit to the right of its entry line 5 Each tab has a SAVE button that is used to save that tab s configuration data after it is entered IMPORTANT Make sure you save the configuration data that you entered before you continue to another tab 6 When all applicable tabs have been configured you can click the APPLY SETTINGS TO CONSOLE button to save all of the configuration data to the console TIP It ...

Page 19: ...ted to the console Enter 1 32 Totalexternalrelays Thisfield showsthe number of externaloutput relaysconnected to the console Enter 1 32 Totaldispensers Thisread only field showsthe number of pumpsconfigured for reconciliation autocalibration Totalsensors Thisfield showsthe number of environmentalsensorsconfigured in the console Optionalcards Select the applicable radio button None Modem for SMS fu...

Page 20: ...elds have selections but not Alarm settings Tolerance Leak threshold with default values Changes to level and or volume unit and number of decimals can automatically change with the selection M2051 EU Rev 1 Dover Fueling Solutions Page 20 ...

Page 21: ...llow and red lines Recommended setting 10 mm Leak threshold liters Used for the DynamicTankLeakDetection function Definesthe maximum leakrate per hour that can be detected A lossover that threshold willbe considered asan unregistered sale and willabort the DynamicLeak test Recommended setting 20 liters TankLeakDetection The console automaticallystartsa tankleaktest refer to the US EPA procedure wh...

Page 22: ...isisthe threshold for the tankleaktest Click Save when you complete the System tab configuration The system will also show the status of the Dip switches 1 2 6 1 3 Protocols This section specifies the protocol to use to communicate with a POS point of sale system or a FCC forecourt controller system M2051 EU Rev 1 Dover Fueling Solutions Page 22 ...

Page 23: ...Baud rate Parity Data bits Stop bits Thesesfieldsare in operation if serialcommunication hasbeen selected Configure the settingsfor the serialports Enable Gilbarco Set Commands Select thisbutton for a range of GVR TLS350 set commandsto be used Printer Connection Select None If no printer isconnected USB If a printer isconnected through the USB port COM1 COM2 If a printer isconnected to the serialp...

Page 24: ... Save New button l In the bottom panel n Add the applicable tanks to the Tank Group n Click the Save icon on the right side of the panel n Click Apply settings to console to complete the procedure To delete a group click the Delete icon on the right side of the panel 6 1 5 Shifts The Shifts screen is used to configure shift reports A shift report shows the tank contents at the beginning and end of...

Page 25: ...iles given bythe server administrator Folder The folder in the server where the filesare to be sent provided bythe server administrator optional can be left blank User User name provided bythe server administrator Password Password provided bythe server administrator ID Console identifier If set to 0 the FTP transfer getsdisabled Port FTP port provided bythe server administrator Interval How often...

Page 26: ...er Password Password provided bythe mailServer Port SMTP port provided bythe mailServer Enable SSL Activate it for SSL connections Use the TEST button to send a test email to a specified recipient REMINDER The recipient must first be configured under Contacts on page 29 Click Save when you complete the SMTP tab configuration 6 1 8 Site Mapping for Reconciliation Autocalibration mode only A POS FCC...

Page 27: ...s Fueling Positions that are connected to the tanks monitored bythe console Maxnozzles Identifiesthe maximum number of nozzlesfor each pump Click Save when you complete the top section of the Site mapping tab configuration 6 1 8 1 Map Dispensers and Nozzles to Tanks 1 Select a Dispenser 2 Map each Nozzle to a Tank 3 The offset is the meter drift value of the dispenser the meter drift is set during...

Page 28: ...om the drop down list TLGmodel Console Model LX4 Address node The addressnode of the console in the IFSF network Thismust be set correctlyfor the POS to connect with the console TLGserial Serialnumber of the console Password Password required bythe POS in to make the connection TLGtype Type of console LX4 Click Save when you complete the IFSF tab configuration M2051 EU Rev 1 Dover Fueling Solution...

Page 29: ...block on the Main Board in the console When all applicable tabs have been configured click the APPLY SETTINGS TO CONSOLE button 6 2 Notifications Menu 6 2 1 Contacts When the contacts tab is selected all contacts that have been entered can be seen M2051 EU Rev 1 Dover Fueling Solutions Page 29 ...

Page 30: ...ation for a new contact name The New Contact window will come into view Complete the fields l Name l Email To receive notifications by email Click Save when you complete the New Contact configuration 6 2 2 Notifications Set up the contact name s and notification type for each of the Notification Events M2051 EU Rev 1 Dover Fueling Solutions Page 30 ...

Page 31: ...gured in Site Info on page 19 will show in the Tabs bar 2 Select a Tank to configure 3 An information bar below the tabs bar will show the Height and Max Volume of the selected tank This is read only data from the last line of the tank strapping table Straptable on page 36 6 3 1 Settings 4 The bar below the information bar shows the configuration parameter selections Settings is the first selectio...

Page 32: ... value is used to calibrate the water float Possible value range 5000 mm 197 in g Water Min Float Level This is the threshold to set the water volume at zero and show the water level l If Water level from probe water offset Water Min Float level the Water volume and Water level will be shown l If Water level from probe water offset Water Min Float level the Water volume will not be shown but the W...

Page 33: ... will adjust automatically b Click the Edit icon for one of the values Enter the correct value in the pop up Click OK to save the value The other values for that parameter will adjust automatically 2 Click Save when you complete the Thresholds configuration NOTE From the top Threshold down each of the Threshold value sets Level Volume and must be lower than the one above it For example the Low Thr...

Page 34: ...y Values The density values as read by the sensor l Density This is the density value at ambient temperature l TC density This is the density value compensated at reference temperature 4 Use the swipe button to select the density flag if applicable a Enter a value in the field to self calibrate the sensor b Click Save 5 The Coefficients settings are values that are given with the density sensor a ...

Page 35: ...l relays of the console can be configured in this screen NOTE The External Relays that show must first be set up in Site Info on page 19 The available alarms actions that can be linked to a relay Disabled Low Very high Water No Link Out of scale Very low Ethanol High Probe Communication Not Initialized Click Save when you complete the Relays configuration M2051 EU Rev 1 Dover Fueling Solutions Pag...

Page 36: ...hart from the 3D Laser the field separator needs to be set as Semicolon Select a file from the attachment list 2 You can copy a strapping table from a different tank Click the Copy from tank button and select an available strapping table from the list that comes into view When a strapping table upload is complete the strapping points Index can be seen in the table at the bottom of the screen Use t...

Page 37: ... quantity in gallons liters for each minute to show the end of delivery The recommended value is 20 liters 5 25 gallons l Vapor Recovery system l Evaporation factor This is used only when ACR tank mode is selected to calculate evaporation loss as a percentage of unit volume For diesel products enter 0 for unleaded products enter 0 17 6 3 6 2 Calibration Parameters l Number of segments The tank is ...

Page 38: ...ed some segments can be changed more than the required value 6 3 7 ACR Results 6 3 8 Reconciliation l Test vend This is the quantity of product used in the calibration of hose meters In meter calibration there is a product quantity removed from the tank without a related sale if Unaccounted variance is greater than Test vend threshold then it is reported as Test vend and it is not thought of as a ...

Page 39: ...difference more than this threshold will cause a Loss Alarm l Unaccounted variance If a difference in the daily reconciliation is more than this threshold it will cause an alarm M2051 EU Rev 1 Dover Fueling Solutions Page 39 ...

Page 40: ...ensors the alarm is caused when the sensor contact opens l For Disconnected sensors This applies to sensors that are connected through the I O module The alarm is caused when the communication of the LX4 with the I O is stopped 5 Relay Select if a relay must be started when an alarm is caused 6 Click Save when you complete the Sensor configuration The Sensor Status is shown at the bottom of the sc...

Page 41: ...ard for the product float l Relay 1 Select this option if a relay should be started when the product alarm is caused If no external relays have been configured in the System Settings Site Info menu then it will not be possible to select an external relay in this menu l Position 2 This is the slot position on the CN10 connector or on the I O sensor board for the water float l Relay 2 Select this op...

Page 42: ...umber of the sensor e g 1 2 3 etc 2 Enter a Name for the sensor up to 30 characters 3 Enter the Serial number of the sensor as shown on the sensor body 4 Use the Has Water Float slide button to identify a sensor with a water float 5 Select the Location of the sensor select the tank manhole or sump 6 Enter the Product offset 7 Select a Relay to start when a high product alarm is sensed 8 Enter the ...

Page 43: ...nfiguration 11 The saved Wireless sensor configuration will show at the bottom of the screen 12 Select the Save icon to save the configuration to a connected pc Use the Delete icon to remove this configuration M2051 EU Rev 1 Dover Fueling Solutions Page 43 ...

Page 44: ... are active but they have not been acknowledged l Green There are no alarms for this tank l Grey The tank is disabled The graph on the right side of the screen will scroll automatically to show the information that follows l Product water height l Product volume Product volume TC l Water volume l Density TC density l Temperature M2051 EU Rev 1 Dover Fueling Solutions Page 44 ...

Page 45: ... to show information on the status of the leakage function The user can manually start and stop a leak test from this menu l Autocalibration Click the Autocalibration drop down menu to show information on the status of the autocalibration function Tank inventory is shown at the bottom of the page TC volume refers to the temperature compensated volume This is calculated through the API tables M2051...

Page 46: ...Section 9 Tank Group Status A summary of the tank group is shown on this screen l Gross volume at 15C l Water volume l Mass in Kg M2051 EU Rev 1 Dover Fueling Solutions Page 46 ...

Page 47: ... can be made for eight 8 types of information l Tank inventory History l Tank Alarms l Sensor Alarms l Product Deliveries l Leak Tests l Pump Sales l Shifts l Reconciliation 10 1 History M2051 EU Rev 1 Dover Fueling Solutions Page 47 ...

Page 48: ...t a From Date for your report l Select to see the data in a Table or Graph l Push the Filter button to show the data The image below shows data as a Graph l The History Report can be exported to a csv format that can be saved in a spreadsheet or text editor Click the CSV Export button to continue M2051 EU Rev 1 Dover Fueling Solutions Page 48 ...

Page 49: ...aved in a spreadsheet or text editor Click the CSV Export button to continue 10 3 Sensor Alarms 1 Select a Sensor from the drop down or use the swipe button to select All sensors 2 Use the date picker to select a From Date and To Date for your report 3 Push the Filter button to show the data 4 The Sensor Alarms Report can be exported to a csv format that can be saved in a spreadsheet or text edito...

Page 50: ... select a From Date and To Date for your report 3 Push the Filter button to show the data 4 The Delivery Report can be exported to a csv format that can be saved in a spreadsheet or text editor Click the CSV Export button to continue M2051 EU Rev 1 Dover Fueling Solutions Page 50 ...

Page 51: ...be saved in a spreadsheet or text editor Click the CSV Export button to continue This report will show the results of leak tests that have been done in the tanks The report will show l The start and end time of the test l The Leak threshold l The volume difference between the start end at ambient temperature and temperature compensated l The result of the test and if the test was aborted M2051 EU ...

Page 52: ...eport can be exported to a csv format that can be saved in a spreadsheet or text editor Click the CSV Export button to continue 10 7 Shifts This report will show the shifts related to specified tanks l Select a Tank Number from the drop down or use the swipe button to select All tanks l Use the date picker to select a From Date and To Date for your report l Push the Filter button to show the data ...

Page 53: ... up to that hour cumulative figure l The volume the level and the temperature at the end of the hour l The cumulative dispenser sales field Sales up to that hour l The difference in liters because of the temperature difference between the current hour and the hour before l The difference in liters because of the evaporation between the current hour and the hour before only if an evaporation factor...

Page 54: ... as a of tank sales l Deliveries The quantity of liters delivered l Delivery var variance This is the Delivery variance This is calculated as the difference between ATG measured delivery and invoiced delivery invoice detail entered manually during delivery report The result is shown in liters and as a of tank sales l Tank depletion The quantity of liters physically kept in the tank l Pump sales Th...

Page 55: ... l Pump calib calibration This is a difference because of the dispenser meter drift this is only applicable if a meter offset has been programmed in the Site Mapping l Theft This is a difference that was recorded as a theft it will be necessary for the Unexpected Sales threshold to be programmed in the Reconciliation settings in the Tank Setup l Unaccounted var variance This is calculated as n Una...

Page 56: ... Use the calendar and clock tools to select the date and time 2 Select the applicable time zone from the drop down 3 Click Save The console application will restart 11 2 Network Configuration 1 Enter the network parameters into the applicable fields 2 Click Save when you have completed all applicable fields M2051 EU Rev 1 Dover Fueling Solutions Page 56 ...

Page 57: ...n this section the numeric password to get access to the Maintenance section on the Graphical User Interface of the console can be changed The timeout session gives the time that the user can be logged in to the Maintenance section before the system automatically logs the user out M2051 EU Rev 1 Dover Fueling Solutions Page 57 ...

Page 58: ... password for the selected user Enter the New password Enter the new password again in the Confirm field Click Save when you have completed all fields TIP As you type your password only neutral bullet characters will show e g Select the eye icon to show the password characters as you type M2051 EU Rev 1 Dover Fueling Solutions Page 58 ...

Page 59: ...Section 13 Logout Select Logout from the Main Menu The Login screen will come into view Click the Logout button to log out of the console M2051 EU Rev 1 Dover Fueling Solutions Page 59 ...

Page 60: ...Section 14 Guest Account A Guest account only gives access to the Tank Status page and a view of data from Reports M2051 EU Rev 1 Dover Fueling Solutions Page 60 ...

Page 61: ... steps to send this data to Technical Support IMPORTANT You must have a USB device with at least 50 MB of free space available The USB device must be formatted to FAT32 Connect the USB device to a PC Put a new folder on the USB device and give it the name lx support make sure you use lower case Eject the USB device from the PC Connect the USB device to the console see General Indications for the l...

Page 62: ...y Changes 0 1784 8 19 2020 Initial Release 1 1836 12 3 2020 Added Autocalibration and Recon ciliation Updated screens and pro cedures NOTE It is possible that older software versions might not support all features M2051 EU Rev 1 Dover Fueling Solutions Page 62 ...