Trouble shooting
Symptom
Cause
Possible solution
An
symbol appears in
the upper left corner of the
display
The dispenser indicates that
user intervention is required.
Touch the
symbol and follow the
instuctions on pages 14 and 19 of
this manual.
One of the messages
‚Flushing is required‘
or
‚Cleaning and flushing is
required‘
appears on the display.
The respective cleaning
program must be performed.
Press the upper center of the touch
screen and follow the instructions,
see page 15 of this manual.
Error 30 is shown on the
display.
The temperature inside the
ingredient storage is too high.
Check / clean the air filter
(see page 18).
If the problem persists contact your
Cafitesse-system-supplier.
Milk leaks from the product
outlet.
Incorrectly installed ingredient
(milk) pack.
Check if the red ring of the dosing
tube is turned completely (see the
instructions on the package).
Water leaks from the hot
water outlet or a product
outlet.
Scale particles block the
respective outlet valve, it
cannot close completely.
Perform the program ‚Flushing‘.
If the problem persists contact your
Cafitesse-system-supplier.
The dispenser does not
respond to pressing a button
or touch screen input.
A software jam has occured.
Reset the dispenser:
Disconnect the power supply and
connect again after 5 seconds.
If the problem persists contact your
Cafitesse-system-supplier.