Electrical System
SP000935
Page 94
Actuator - Wind Direction Control
Change of discharged airflow according to selected wind
direction mode
Change of wind direction: Direction changes in the order of
VENT
o
BI-LEVEL
o
FOOT
o
FOOT/DEF
o
VENT.
Actuator - Temperature Control
Change of discharged air temperature by controlling the position
of temperature control door.
Actuator - Wind Direction Control
Actuator - Temperature Control
FG001361
Figure 78
Wind Direction Mode
Output Terminal
Voltage
Vent
c (+): CN10-10
b (-): CN10-4
0.5 ± 0.2V
Bi-level
1.3 ± 0.2V
Foot
2.45 ± 0.2V
Foot/def
3.5 ± 0.2V
Def
4.5 ± 0.2V
Set Temperature
Output Terminal
Voltage
Max cooling
c (+): CN10-9
b (-): CN10-4
Below 0.4V
Max heating
Above 4.5V