Electrical System
Page 117
SP000935
3.
If refrigerant does not flow freely into system, try starting
engine first before operating air conditioner.
•
Temperature control switch setting: Maximum Cooling
Blower Speed Setting: Hi (3 step)
Engine Speed: 1,300 - 1,500 rpm
4.
Open the manifold gauge low side valve and charge
system to standard capacity.
NOTE:
These standards are for outside temperatures
between 30° - 35°C (86° - 95°F). The gauge
readings may vary for extreme temperature
conditions.
5.
Close low-pressure side valve.
6.
Shut off engine and close refrigerant supply container
adapter valve. Disconnect manifold gauge hoses from
vehicle.
WARNING!
When charging refrigerant system with the engine
running:
•
Always keep refrigerant supply container in
the upright position.
•
Never open the high side pressure valve.
Gauge Dial
Standard Reading
High Side Gauge
13 - 20 kg•cm
2
(185 - 285 psi)
Low Side Gauge
1.5 - 3.5 kg•cm
2
(22 - 50 psi)
WARNING!
•
When outside temperature is low, warm the
refrigerant supply container with warm
water not exceeding 40°C (104°F). Do not
allow water to come in contact with the
charging adapter valve handle.
•
When outside temperature is high, cool off
refrigerant supply container and condenser
to aid the refrigerant charging process.
Summary of Contents for DX225LC
Page 1: ......
Page 3: ...Electrical System SP000935 Page 2 MEMO ...
Page 7: ...Electrical System SP000935 Page 6 MEMO ...
Page 9: ...Electrical System SP000935 Page 8 ...
Page 56: ...Electrical System Page 55 SP000935 ...
Page 64: ...Electrical System Page 63 SP000935 ...
Page 82: ...Electrical System Page 81 SP000935 ...
Page 129: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC MEMO ...
Page 131: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC MEMO ...
Page 133: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC Page 6 ...