Electrical System
Page 85
SP000935
SELF-DIAGNOSTIC FUNCTION
e-EPOS Controller
The system operation status and malfunction codes can be
checked through the display on top of the e-EPOS controller box
the rear cover behind the operator's seat.
1.
Power Monitor
This LED is turned "OFF" when the input voltage to the
e-EPOS controller is below 18.5 ± 1 V or above 32.5 ± 1 V.
Stays "ON" while in normal range.
2.
Engine Speed Monitor
This LED light flashes according to the engine speed. The
flashing interval is proportional to the engine speed.
1
2
4
3
FG000588
Figure 68
Reference
Number
Description
1
Upper Digit
2
Lower Digit
3
Engine Speed Monitor LED
(Flash Interval Increases With
Engine Speed.)
4
Power Monitor (Stays "ON" While
Power Is In Normal Range,)
Reference
Number
Description