Electrical System
SP000935
Page 106
Error codes
NOTE:
The position error means that it fails to move to
designated place in 40 seconds.
Sun sensor displays E8 in case of no sunlight.
2 and more fails: Codes concerned blinks twice at a
time.
Ambient Temperature Display
Selection of both the SEL and MODE switch for more than 3
seconds indicates the ambient temperature in the set
temperature display department.
- Range of temperature display: -40 - +60°C
NOTE:
Display of ambient temperature may be released in
the same way for its entry way.
It returns automatically to default mode 5 seconds
after entering the ambient air temperature display
mode.
Code
Description
E0
Normal
E1
Internal air temperature sensor short
E2
Internal air temperature sensor open
E3
Ambient air temperature sensor short
E4
Ambient air temperature sensor open
E5
Duct sensor short
E6
Duct sensor open
E7
Sun sensor short
E8
Sun sensor open
E9
Water temperature sensor short
E10
Water temperature sensor open
E11
D.P.S open
E12
Position error of wind direction actuator
E13
Position error of temperature control actuator
0.5
E1
E1
E2
E2
E3
0.5
FG001067
Figure 90
Summary of Contents for DX225LC
Page 1: ......
Page 3: ...Electrical System SP000935 Page 2 MEMO ...
Page 7: ...Electrical System SP000935 Page 6 MEMO ...
Page 9: ...Electrical System SP000935 Page 8 ...
Page 56: ...Electrical System Page 55 SP000935 ...
Page 64: ...Electrical System Page 63 SP000935 ...
Page 82: ...Electrical System Page 81 SP000935 ...
Page 129: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC MEMO ...
Page 131: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC MEMO ...
Page 133: ...SP000936 Electrical Schematic DX180LC DX225LC DX225NLC DX255LC Page 6 ...