1835-067-A-9-18
5
9
1.
Press and enter your four-digit MASTER CODE
(beep
).
The LCD display will show the 10-digit phone number or system ID number.
6.1.7 Display DKS Data over IP Phone Number or System ID Number
This will allow you to see the
DKS Data over IP
issued 10-digit phone number or system ID number that has been programmed
into the telephone entry system.
1.
Press and enter your four-digit MASTER CODE
(beep
).
The LCD display will show one of the following and the entry system will BEEP accordingly:
6.1.8 Test Connection to DKS Data over IP
This will allow you to test the connection to the
DKS Data over IP
or display problems that may have occurred.
Note:
The display will show C's (C C C C C C C C C C) if a phone number or system ID has
NOT
been programmed.
Use the following sequence to turn
DKS Data over IP
OFF
or
ON
.
If you are going to use the RS232 connection for any other RS232 functions other than
DKS Data over IP
(e.g., connecting a PC
directly to the phone entry system via the RS232 terminal), the
DKS Data over IP
must be turned
OFF
.
The
DKS Data over IP
must be
ON
to use the entry system with
DKS Data over IP
.
Note:
When section 3.2.10 (DKS Data over
IP Phone Number or System ID Number is programmed, the
DKS Data over IP
is
automatically
turned
ON
.
If there is
NOT
a valid 10 digit system phone number or system ID number in memory, the system will emit three (3) short
beeps.
Beep ... Beep ... Beep
6.1.9 Turn DKS Data over IP OFF or ON
1.
Press and enter your four-digit MASTER CODE (
beep
).
2.
Press (
beep
) to turn
OFF
, OR (
beep
) to turn
ON.
3.
Press together to end this programming sequence (
beeeeeep
).
N
Y
h
l
h
i
DKS D
IP
d
l
bl
Note:
If there is pending data to be transfered when this test is performed, the data transfer will occur.
System is Registered
-
(beep)
one beep
- System is registered and communication to
DKS Data over IP
is good.
Check Registration
-
(beep-beep)
two beeps
- Make sure your registration is current and this system is set to
DKS Data over IP
on the
registration screen. Also, be sure that the system phone number or ID number and the
master code are set the same on
DKS Data over IP
and the entry system.
Program 10 Digit ID
-
(beep-beep-beep)
three beeps
- There is not a valid 10-digit ID in the entry system memory. (see section 3.2.10)
Turn DKS Data over IP On
-
(beep-beep-beep-beep)
four beeps
- There is a valid 10-digit ID, but
DKS Data over IP
is turned OFF. (see section 6.1.9 below)
No DKS Data over IP Contact
-
(beep-beep-beep-beep-beep)
five beeps
-
Communication
to
DKS Data over IP
could not be made.
0
0
?
?
?
?
?
?
?
?
?
?
?
?
1
6
5
9
2
5
5