[CHAPTER 6 FUNCTION TABLE & DESCRIPTION]
6-5 |
DOOCHPUMP
DISPLAY
Name
Range
Factory Setting
Change
on
Operation
Ref.
Page
dr-38
Waiting Time of Automatic
Restart after Trip
1~250[sec] 10
O
dr-40
Drive Control Mode
0~1
0
X
dr-41 Torque
Boost
Amount
0~10.0[%]
2.0
X
dr-42 Start
Frequency.
0.10~40.00[Hz]
0.50
X
dr-43
Max Operation Freq.
40.0~Rated Freq. of
Motor [Hz]
60.00 X
6-20
6-21
dr-44 Switching
Frequency.
1.0~15.0[kHz]
5.0
O
dr-50 Fan
Operation
Type
0~2
1
O
dr-51
Power Consumption
Correction
0.0~1000.0 100.0 O
dr-52 Output
Power
Indication
0.0~100.0[kW]
-
dr-53
Indicating Accumulated
Mega Wh
0~9999[MWh] -
dr-54
Indicating Accumulated
Killo Wh
0~9999[kWh] -
dr-55
Temp. of Power
Semiconductor
0~200
℃
-
6-22
dr-56 Ambient
Temp.
Display
0~200
℃
-
dr-57 Output
Power
Display
0.0~500.0[V]
-
dr-60 V1
Min
Input
Voltage
0.0~5.0[V]
0.0
O
dr-61
Corresponding Freq.
toV1 Min Input Voltage
0.00~30.00[Hz] 0.00 O
dr-62 V1
Max
Input
Voltage
5.1~10.0[V]
10.0
O
dr-63
Corresponding Freq. to
V1 Max Input Voltage
30.01~ Rated Freq. of
Motor [Hz]
Rated Freq. of
Motor
O
dr-64
I1 Min Input Current
0~10[mA]
4
O
dr-65
Corresponding Freq. to I1
Min Input Current
0.00~30.00[Hz] 0.00 O
dr-66
I1 Max Input Current
11~20[mA]
20
O
dr-67
dr-70
Corresponding Freq. to I1
Max Input Current
30.01~ Rated Freq. of
Motor [Hz]
Rated Freq. of
Motor
O
-
0~9999
Year Display
dr-71 Month/Date
Display
01.01~12.31
-
dr-72 Hour/Minute
Display
00.00~23.59
dr-89
Initializing Integrated Watt
0~1
-
dr-90 Initialization
Code
0~1
0
X
0 X
6-23
Summary of Contents for Q-Drive NQ-0075-S