OPERATING WITH LAGO FB OT+ REMOTE CONTROL (OPTIONAL)
A remote control (
LAGO FB OT+
) can optionally be supplied together with
BioClass iC 66
boiler. This
remote control can be used to fully operate the boiler from anywhere in the room in which it is installed.
The
LAGO FB OT+
remote control regulates the parameters of heating circuit and the domestic hot water
production.
The
LAGO FB OT+
remote control is not compatible with the boiler's
iConnect
connectivity, so if the
boiler is already registered in the
iConnect
application, it will not be possible to install a
LAGO
remote
control, and viceversa. If you want to install a
LAGO FB OT+
remote control, first unregister the boiler
from
iConnect
using the "
iCon
" option in the "Configuration" menu
(see "Configuration Menu")
.
This remote control allows the hours of comfort to be programmed for heating circuit, regulating the
installation to the particular requirements of the building by measuring the room temperature and
consequently adapting the installation temperature. The remote control can also be used to regulate the
hot water and heating temperatures set point at any time, and for viewing the different boiler operation
parameters. It also warns of any functioning anomalies affecting the boiler.
The
LAGO FB OT+
remote control may optionally be connected to an outdoor temperature sensor, for
measuring the temperature around the building. With this option installed, the remote control can adjust
the building comfort level according to the weather conditions, optimising fuel consumption and heating
comfort in the building.
The
LAGO FB OT+
remote control takes over the control of the boiler when it is connected. The different
selectable temperatures boiler of the boiler must be set at the remote control. It is easy to install, requiring
only 2 wires for communication between the boiler and the
LAGO FB OT+
control, by connecting the two
wires on terminal strip
J5
(see
“Electrical Connection Diagram”)
. For a correct installation and functioning,
read carefully the instructions within the remote control.
The following sections contain a general explanation of the different operating modes and options of
LAGO FB OT+
remote control.
Operation of the heating circuit
The maximum temperature for heating circuit, the operating period of time and the desired room
temperature can be set at remote control.
LAGO FB OT+
remote control will calculate the boiler
temperature required at each particular time, depending on the temperature of the room and it will activate
or deactivate the heating demand depending on the heating times and room temperatures programmed.
DHW service function
When
BioClass iC 66
boiler is installed together with a DHW tank the desired DHW temperature and the
desired periods of time for DHW service must to be set at
LAGO FB OT+
remote control.
LAGO FB OT+
remote control regulates the DHW tank temperature and enables or disables the DHW service according
to the time periods scheduled.
NOTE: The installation of a LAGO FB OT + remote control is not compatible with the iConnect
connectivity of the boiler.