27
BIOCLASS iC 66
5.3
Boiler temperature set point selection
Boiler temperature set point selection is made by the tactile selector shown in the picture. Press “
+
”
and “
-
“ buttons to increase or decrease the set point desired. Few seconds after the desired set point
temperature is adjusted the display returns to main position. The range of values for boiler temperature
set point is OFF, 65 - 80 ºC.
It is also possible to set boiler temperature set point browsing through the
“User Menu”
by pressing
MENU
button. When parameter
“Boiler set point temperature”
is displayed, the boiler temperature set
point is set by pressing “
+
” and “
-
“ buttons.
When the operation mode is activated according to the external climatic conditions by means of
parameter
P.10
of the "Technical Menu" and an operation K curve is selected for heating Zone 1
(parameter
P.45
of the "Technical" menu), the The temperature of the water in the same will be
calculated using the K curve, therefore, by selecting the boiler temperature setpoint, it will only be
possible to select the activation ("
ON
") or deactivation ("
OFF
") of the heating service of said boiler.
zone.
It is possible to disable the heating service of the boiler (
Summer
mode
) by setting to "
OFF
" the
boiler temperature set point by pressing “
-
“symbol for heating
(18)
.
5.4
DHW temperature set point selection (with DHW tank installed only)
DHW temperature set point selection is made by the tactile selector shown in the picture. Press “
+
”
and “
-
“ buttons to increase or decrease the set point desired. Few seconds after the desired set point
temperature is adjusted the display returns to main position. The range of values for DHW temperature
set point is OFF, 15 - 65 ºC.
It is also possible to set the DHW temperature set point browsing through the
“User Menu”
by pressing
MENU
button. When parameter
“DHW temperature set point”
is displayed, the DHW temperature set
point is set by pressing “
+
” and “
-
“ buttons.
It is possible to disable the DHW service by setting to "
OFF
" the DHW temperature set point by pressing
“
-
“ for DHW
(19)
.