Fig. 6A
Warning Horn
The machine is equipped with a horn for signaling warning
conditions. Use this check box to enable or disable the warning horn.
Zero Speed
Checking the “Zero Speed” box allows the user to input a speed of
zero for the platen in the recipe setup. This is often used to verify
pressure of the machine and its load cell readings.
Maintenance Schedule
The “Maintenance” screen (Fig. 6A and Fig. 6B) allows you to
define specific maintenance parameters including Platen Grease,
Clean Plunger and Mandrel, Loadcell Calibration, Replace Koby Filter,
Replace Rubber Pad, Annual Maintenance, Replace Air Cleanse Filter,
and EZ Check Wear Test Kit. This section is also used to reset values
after set parameters are reached.
21
Platen Grease
The Platen Grease maintenance is tied to the numbers of hours the
Platen is rotating. To set the Platen Grease maintenance interval:
1. Use a stylus to press the number located under “Hour Interval”
tab. This will access the keypad for data entry.
2. Use the keypad to set hours of use before changing Platen
Grease. The recommended interval is 40 hours. This can be
modified as needed.