CT100G Series Inverter
CHAPTER 4 FUNCTION PARAMETER TABLE
- 49 -
Functio
n code
Name
Detailed instruction of parameters
Default
value
Attrib
ution
F09.22
PIDparameter change bias 2 F10.21
~
100.0%
80.0
○
F09.23
PID initial value
0.0%
~
100.0%
0.0
○
F09.24
PID initial value keep time
0.00
~
650.00
0.00
○
F09.25
FWD max bias of two output
0.00
~
100.00%
1.00
○
F09.26
REV max bias of two output
0.00%
~
100.00%
1.00
○
F09.27
PID Integral attribute
Unit place: integral attribute 0: invalid 1:
valid
Ten place: output arrive limit, stop integral
or not
0:not stop 1:stop
00
○
F09.28
PID stop calculation
0: calculate at stop
1: calculate at stop
0
○
F10 Group
Wobble, step length and count value
F10.00
Wobble set mode
0:Corresponding to centre frequency
1:Corresponding to maximum frequency
0
○
F10.01
Wobble range
0.0%
~
100.0%
0.0
○
F10.02
Saltation frequency amplitude 0.0%
~
50.0%
0.0
○
F10.03
Wobble cycle
0.1s
~
3000.0s
10.0
○
F10.04
Wobble triangular wave rise
time
0.1%
~
100.0%
50.0
○
F10.05
Set length
0m
~
65535m
1000
○
F10.06
Actual length
0m
~
65535m
0
○
F10.07
Pulse per meter
,
unit:0.1
0.1
~
6553.5
100.0
○
F10.08
Set count value
1
~
65535
1000
○
F10.09
Designated count value
1
~
65535
1000
○
F11 Group
Multi-step speed and PLC
F11.00
Multi-step speed command 0
-100.0%
~
100.0%
(
100.0% corresponding to maximum
frquencyF00.06
)
0
○
F11.01
Multi-step speed command 1
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.02
Multi-step speed command 2
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.03
Multi-step speed command 3
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.04
Multi-step speed command 4
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.05
Multi-step speed command 5
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.06
Multi-step speed command 6
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.07
Multi-step speed command 7
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.08
Multi-step speed command 8
-100.0%
~
100.0%
(
100.0% of max frequency F00.06
)
0
○
F11.09
Multi-step speed command 9 -100.0%
~
100.0%
0
○