CT100G Series Inverter
CHAPTER 4 FUNCTION PARAMETER TABLE
- 31 -
Functio
n code
Name
Detailed instruction of parameters
Default
value
Attrib
ution
F00.00
Motor control mode
0:speed sensorless vector control
1:reserved
2:V/F control
2
☆
F00.01 Run command channel
0: keypad run command channel (LED
off)
1: terminal running command channel
(LED on)
2: 485 run command channel (LED
flickering)
0
○
F00.02
Main frequency source X
0:digital setting ( pre-set frequency
F00.09,UP/DOWN change, no power down
memory)
1:digital setting ( pre-set frequency
F00.09,UP/DOWN change, with power
down memory)
2:AI1
3:AI2
4:keypad potentiometer AI0
5:high speed pulse input (DI5)
6:multi-step speed
7:simple PLC
8:PID
9:485 communication
0
☆
F00.03
Auxiliary frequency source Y
Same as F00.02main frequency
0
☆
F00.04
Reference
object
of
Y
frequency source
0: relative to the max. frequency
1: relative to frequency source X
0
○
F00.05
Frequency source selection
Unit: frequency source selection
0: main
1: main and auxiliary operation ( decided
by ten)
2: main<--> auxiliary
3: main<-->main and auxiliary operation
4:auxiliary<-->main and auxiliary operation
Ten: main and auxiliary operation
relationship
0:main + auxiliary
1:main- auxiliary
2:max
3: min
00
○
F00.06
Max. frequency
50.00Hz
~
500.00Hz
50.00
☆
F00.07
Upper limit frequency
F00.08
~
F00.06 (Max. frequency)
50.00
○
F00.08
Lower limit frequency
0.00Hz
~
F00.07 (upper limit of running
frequency)
0.00
○
F00.09
Frequency pre-setting
0.00Hz
~
F00.06 (Max. frequency)
50.00
○
F00.10
Run direction
0: positive
1: reverse
0
○
F00.11
Carrier frequency
0.5kHz
~
16.0kHz
6.0
○
F00.12
Carrier frequency adjusted
according to temperature
0:no
1:yes
1
○
F00.13
Motor selection
0:motor 1
0
☆