The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.
■
■
Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making engine-starting difficult.
■
■
Remove the drain screw of the carburetor.(See Fig.
6
-
q
)
q
DRAIN SCREW
■
■
Change engine oil.
■
■
Check for loose bolts and screws, tighten them if necessary.
■
■
Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER
TO CLEAN GENERATOR !
■
■
Pull starter handle until resistance is felt, leaving handle in that position.
■
■
Store generator in a well ventilated, low humidity area.
When generator engine fails to start after several attempts, or if no electricity is available at the output
socket, check the following chart. If your generator still fails to start or generate electricity, contact your
nearest DOLMAR factory or authorized service center for further information or corrective procedures.
11. TROUBLESHOOTING
10. PREPARATION FOR STORAGE (See Fig.
6
6
)
When No Electricity Is Generated at Receptacle :
When Engine Fails to Start:
Turn engine switch to "
"(CHOKE) position.
If empty, refill fuel tank making sure not to overfill.
If connected, turn off the power switch on the
connected appliance and unplug.
Remove spark plug and clean electrode.
If the engine oil level is low, add the oil to the
upper level line on the oil gauge.
If loose, push spark plug cap back into place.
Check if engine switch is in its proper position.
Check fuel level.
Check to make sure generator is not
connected to an appliance.
Check spark plug for contamination.
Check engine oil level.
Check spark plug for loose spark plug cap.
Check if the DC circuit breaker is turned off.
Check if the "O_Lod"(overload) is indicated
in the Multi Monitor.
Check AC receptacle and DC terminals for
loose connection.
Check to see if engine starting was
attempted with appliances already
connected to generator.
Depress the circuit breaker into " I " (ON)
position, after making sure the charging
current level is proper and the battery is in
the normal condition.
Stop the engine and check the appliance
and/or generator for overloading.
Secure connection if necessary.
Turn off switch on the appliance, and
disconnect cable from receptacle. Reconnect
after generator has been started properly.
GE-2800 IS(GB)̲GU2127 05.8.31 6:40 PM ページ16
Summary of Contents for GE-2800 IS
Page 3: ...LW A...
Page 139: ...1 2 GB GB GB GB GB GB GB GR GR GB GB GB GB GB GB GB 1 3 1m 1m...
Page 140: ...3 GB GB GB GB GB GB GB GR GB GB GB GB GB GB GB GB...
Page 143: ...5 2 t q 2 y q 6 2 u q w e 4 1 6 GB GB GB GB GB GB GB GR GR GB GB GB GB GB GB GB K 3...
Page 149: ...12 GB GB GB GB GB GB GB GR GR GB GB GB GB GB GB GB 6 20 100 50 100 200 500 1000 24...
Page 153: ...16 GB GB GB GB GB GB GB GR GR GB GB GB GB GB GB GB 6 6 q q DOLMAR 11 10 6 6 O_Lod AC DC OFF...
Page 234: ...2 RU 1 1m 1m GE 4300 IS GU2127 Ru 05 8 29 4 02 PM 2 Black...
Page 235: ...3 RU GE 4300 IS GU2127 Ru 05 8 29 4 02 PM 3 Black...
Page 236: ...4 RU P r COP COS r f r U r I r H max T max m GE 4300 IS GU2127 Ru 05 8 29 4 02 PM 4 Black...
Page 238: ...6 RU 4 5 2 t q 2 y q 6 2 u q w e 3 GE 4300 IS GU2127 Ru 05 8 29 4 02 PM 6 Black...
Page 244: ...12 RU 6 20 100 50 100 200 500 1000 24 GE 4300 IS GU2127 Ru 05 8 29 4 03 PM 12 Black...
Page 247: ...15 RU 8 3 10 9 GE 4300 IS GU2127 Ru 05 8 29 4 03 PM 15 Black...
Page 248: ...16 RU 10 6 6 6 6 6 6 6 q q 11 DOLMAR O_Lod GE 4300 IS GU2127 Ru 05 8 29 4 03 PM 16 Black...