42
DC-ITD-CL4andCL8MAN01.A
www.dodtec.com
NOV 2018
815-788-5200
CL4 & CL8 Manual
a)
Push the USB Memory Stick straight up ensuring the USB Memory Stick and slot are aligned properly.
Figure 6.3
Section 5.5 describes viewing the files stored on the USB Memory Stick on the touch screen. Appendix F
details the data stored on the USB Memory Stick and how to access it on a personal computer.
6.7 Apply grease periodically
The cam attached to the gate motor should be greased every 6 months to prevent wear. Apply a small
amount of number 2 type petroleum or synthetic grease (such as McMaster Carr #1378K27) to the rounded
portion of the cam.
–
See Figure 6.4
Top of gate mechanism
Bottom of gate mechanism
Figure 6.4 -Grease may be applied either from the top of the gate mechanism or the bottom.
6.8 Fuse Replacement
The system power is fused with a 2 amp fast-acting (5x20mm) fuse.
DO NOT REMOVE