39
DC-ITD-CL4andCL8MAN01.A
www.dodtec.com
NOV 2018
815-788-5200
CL4 & CL8 Manual
ChemLogic Paper Tape Installation Procedure
A.
From the setup menu touch the ‘Load Tape’ button (section 5.2.
3)
B.
Open the maintenance door. (Section 6.1)
C.
On the screen touch the ‘OPEN/CLOSE GATE’ button to open the gate
D.
Remove the old take-up reel by gently pulling and dispose of properly
E.
Remove the empty tape reel and install on top as the new take-up reel.
F.
Secure the new ChemLogic tape reel on the bottom as shown in figure 6.1. The tape should be around
the bottom in a clockwise direction as shown.
G.
Feed the tape as shown with the arrows in figure 6.1.
1.
From the bottom reel
2.
Around the bottom tape guide
3.
Through the opening between the optic blocks
4.
Between the rubber roller and the capstan
5.
Around the top of the upper tape guide
6.
Fold the end of the tape and insert into the slot in the empty tape reel. Be sure the tape is wound
clockwise around the take-up reel.
Figure 6.1
H.
Turn the upper wheel clockwise at least 2 full turns to secure the tape
I.
On the screen touch the ‘OPEN/CLOSE GATE’ button to cl
ose the gate
J.
On the screen touch the ‘Reset Counter’ button. (See section 5.2.
3)
Warning:
Keep fingers clear during tape advance.
Upper tape reel
1
2
3
4
5
6
Lower tape reel
Optic Blocks
Bottom tape guide
Top tape guide
Capstan / Rubber roller