23
DMM Technology Corp.
DYN4 AC Servo Drive Instruction Manual
REV. ZM7-A10A
CT1
█ Multiple Drives
Multiple drives can share the same mains power supply. Select MCCB, MC1 and F1 size according to
number of drives. Example. if 2 servo drives are connected, select double the rated MCCB and fuse.
Use a single point star connection from a single relay or strip terminal to distribute power to each servo
drive.
Connect noise filter NF1 individually for each drive.
T
R
S
L2
L1
T4
PE
Main Circuit Power
Supply
Control Logic
Power Supply
A
C
B
T2
PE
Servo Motor
Power
DYN4 Servo Drive
JP3
Servo Motor
A
C
B
Encoder
S
FG
NF1
Mains Supply
R S T
MCCB
MC1
ESTOP
ON
OFF
T
R
S
L2
L1
T4
PE
Main Circuit Power
Supply
Control Logic
Power Supply
A
C
B
T2
PE
Servo Motor
Power
DYN4 Servo Drive
JP3
Servo Motor
A
C
B
Encoder
S
FG
T
R
S
L2
L1
T4
PE
Main Circuit Power
Supply
Control Logic
Power Supply
A
C
B
T2
PE
Servo Motor
Power
DYN4 Servo Drive
JP3
Servo Motor
A
C
B
Encoder
S
FG
F1
F1
Relay
Terminal
NF1
NF1
Note
1. Use a separate NF1 noise filter in-
divitually for each servo drive. Only
connect the noise filter to the logic L1
L2 terminal.
2. For fuse F1, allow 1A per servo
drive connected.
3. Select circuit breaker (MCCB)
and magnetic contactor (MC1) with
enough capacity according to servo
drives connected.
4. Do not daisy chain the R S T or L1
L2 power conenction from one drive
to another.
5. A terminal block can be used in
place of a relay terminal.
Relay
Terminal
Manual
Switch
MC1
NF2
LR1