![DKT Comega OFA-CCD series User Manual Download Page 45](http://html1.mh-extra.com/html/dkt-comega/ofa-ccd-series/ofa-ccd-series_user-manual_2512812045.webp)
DKT A/S
Fanoevej 6
DK-4060 Kirke Saaby
Tlf
Fax
E-mail
Web
+45 4646 2626
+45 4646 2625
www.dktcomega.com
Network Managed Optical Amplifier
User’s Manual Rev 1.3
OFA-CCS/CCD Series
June 2014
45
6
PERFORMANCE CHECK
6.1
Precautions for Testing
In this chapter after completing installation of the Shelf Type EDFA the proper operation,
power supply procedures, monitor connection, start test method, and other instructions are
explained. Before applying power to the Shelf Type EDFA check the Optical cable
connections on the rear panel of the EDFA once more before turning the Power Switch on.
6.2
Power Supply
Below shows the circumstances that occur when the Shelf Type EDFA is first powered up.
Check if the Power Switch on the front panel is in the OFF state.
Connect power-cords to the power sockets on the rear panel.
Turn on the Power Switch on the front panel.
All the LED’s on the front panel turn on.
The LCD on the front panel shows the Start state.
When the Start state of LCD ends, all the LED’s on the front panel turn off and, the
related LED’s turn on.
If the optical input power is normal, the EDFA stays in the “Laser ON” state.
6.3
Primary Test
6.3.1
Required Measuring Instruments
The required measuring instruments and their performances for the Primary Operation of
the EDFA are in Table 10.
Table 9. The Instrument for measuring the performance
Instrument
Performance
Optical Source
or
Optical Transmitter
Input Optical Signal Source to the EDFA
Operational wavelength 1550nm substitution
Optical Variable Attenuator
Controls the optical input power
Optical Power Meter
Measure the optical power
6.3.2
Performance Test
Precaution
Before this test you must insure the conditions below are met.
1) You must always keep clean the surface of the optical connectors.
2) Do not look directly into the optical connector.
3) Do not wipe the surface of the optical connector during the LASER ON state of the
EDFA.