![DKT Comega OFA-CCD series User Manual Download Page 29](http://html1.mh-extra.com/html/dkt-comega/ofa-ccd-series/ofa-ccd-series_user-manual_2512812029.webp)
DKT A/S
Fanoevej 6
DK-4060 Kirke Saaby
Tlf
Fax
E-mail
Web
+45 4646 2626
+45 4646 2625
www.dktcomega.com
Network Managed Optical Amplifier
User’s Manual Rev 1.3
OFA-CCS/CCD Series
June 2014
29
ADMIN:> snmp get trapen 1
--------------------------------------------------------
SNMP Trap enable[1] : [OFF]
SNMP GET TRAPCOMM [Index]
ex)
ADMIN:> snmp get trapcomm 1
--------------------------------------------------------
SNMP Trap Community[1] : [public]
SNMP SET ROCOMM [string]
ex)
ADMIN:> snmp set rocomm public
--------------------------------------------------------
snmp setting is Successful.
SNMP SET RWCOMM [string]
ex)
ADMIN:> snmp set rwcomm private
--------------------------------------------------------
snmp setting is Successful.
SNMP SET TRAPEN [Index] [ON/OFF]
ex)
ADMIN:> snmp set trapen 1 on
--------------------------------------------------------
snmp setting is Successful.
SNMP SET TRAP [Index] [IP Address]
Ex)
ADMIN:> snmp set trap 1 92.168.0.31
--------------------------------------------------------
snmp setting is Successful.
This setting will be applied after reboot.
SNMP SET TRAPCOMM [Index] [string]
ex)
ADMIN:> snmp set trapcomm 1 public
--------------------------------------------------------
snmp setting is Successful.
5.1.1.13
NTP
NTP commend synchronizes the shelf unit
’
s time from time server.
To use the NTP features, user needs to set NTP server and Time zone accordingly.
ex)
ADMIN:> ntp
--------------------------------------------------------
Usage : NTP [ARG1] [ARG2] [ARG3] [ARGx]
ARG1 : GET, SET
ARG2 : GET - SERVER. NTP Server IP Information
TIMEZONNE. Time Zone
SET - SERVER.
TIMEZONNE. Time Zone
ARG3 : SERVER - Enter the IP1.[xxx.xxx.xxx.xxx]
TIMEZONNE - -24 ~ +24
ARGx : SERVER - Enter the IPx.[xxx.xxx.xxx.xxx]
--------------------------------------------------------
NTP SET SERVER [IP1] [IP2] ...[IP5]