DKT Comega OFA-CCD series User Manual Download Page 20

DKT A/S

Fanoevej 6

DK-4060 Kirke Saaby

Tlf
Fax
E-mail
Web

+45 4646 2626
+45 4646 2625

www.dktcomega.com

[email protected]

 
Network Managed Optical Amplifier 

 

User’s Manual Rev 1.3

 

OFA-CCS/CCD Series 

 

June 2014 

 

 

20 
 

 
 
 
 
 
 
 
 
 
 
If you push the Enter switch, the time value is stored. 
 
 
 

4.2.7

 

IP Address   

The IP Address menu is showed IP Address of network. 

 
 
 
 
 
 

 

YYYY MM DD HH MM SS

 

2 0 0 5   0 6   0 9   1 5   0 5   3 0  

55 

YYYY MM DD HH MM SS

 

2 0 0 5   0 6   0 9   1 5   0 5   3 0  

3 0  

IP Address :

 

1 2 3 . 4 5 6 . 0 . 7 8 9  

3 0  

Summary of Contents for OFA-CCD series

Page 1: ...S Fanoevej 6 DK 4060 Kirke Saaby Tlf Fax E mail Web 45 4646 2626 45 4646 2625 www dktcomega com mail dktcomega com OFA CCS CCD Series 1U 2U Shelf Network Managed Optical Amplifier User s Manual June...

Page 2: ...4 How to connect the optical cable 8 3 DESCRIPTION 9 3 1 Summary 9 3 2 Panel Description 9 3 2 1 Front Panel 9 3 2 2 LED State Information 10 3 2 3 Rear Panel 11 4 OPERATION 12 4 1 Summary 12 4 2 LCD...

Page 3: ...5 2 12 Trap 36 5 3 WEB Interface 37 5 3 1 WEB browser 37 5 3 2 Monitoring 38 5 3 3 Parameter 39 5 3 4 Control set 40 5 3 5 Event log 41 5 3 6 IP Login set 42 5 3 7 SNMP set 43 5 3 8 Manual 44 6 PERFOR...

Page 4: ...Panel 9 Figure 3 Rear Panel 11 Figure 4 Shelf Type EDFA Measuring Instrument Setup 46 Table Contents Table 1 The Inventory of Shelf Type EDFA 7 Table 2 Laser On OFF Key Switch 9 Table 3 Control Switc...

Page 5: ...tions such as AC 100V 240V DC 48V 1 3 Mechanical Dimensions and Operational Conditions The Shelf Type EDFA is installable in a 19 1U or 2U Shelf The size is 432 W 375 D 44 or 88 H mm The storage tempe...

Page 6: ...ned on 1 5 Grounding Considerations The Shelf Type EDFA includes Laser Diodes and Photo Diodes those are extremely sensitive to electrical static You must always handle the EDFA with extra care When y...

Page 7: ...check the contents The inventory should be as follows Table 1 The Inventory of Shelf Type EDFA Item Quantity Remarks EDFA Shelf 1 Including EDFA Instructions manual 1 book TEST REPORT 1 booklet Inspec...

Page 8: ...ot liable for repairs or replacement of the unit After connecting the DC power cord to the unit turn on the power switch on the rear panel If LCD on the front panel turns on the system electric power...

Page 9: ...4 menu control switches for selecting the LCD menus a Laser ON OFF key switch an EDFA state indicating LED and optical adapter cassette Laser Down Menu Enter On Off Up Ethernet RS 232C Comm Status Las...

Page 10: ...ower than the minimum input conditions the color of status LED changes green to red see the TEST REPORT The threshold for triggering the loss of input signal alarm is set below the minimum optical inp...

Page 11: ...ting LED for an over current condition of the Pump Laser Diode bias current If the BIAS alarm is activated the color of status LED changes green to yellow TEMP Alarm The internal temperature of the Pu...

Page 12: ...is chapter the operation of the EDFA using the LCD menu will be explained The diagram below shows the operational menu tree selectable Provision EDFA DEACT EDFAACT LASER Laser OFF Laser ON Buzzer OFF...

Page 13: ...trol Status Test Function Setting IP Address You can select any menu by the Menu switch The procedure of selection in the MAIN MENU is as follows Push the Menu switch on the start screen The LCD displ...

Page 14: ...want to change the current state move the cursor by the Up or Down switch to the menu you wish to select From the current state move the cursor by Up or Down switch to the position on the DEACT menu P...

Page 15: ...ol If you push Enter switch the cursor moves to the LASER menu Laser ON From the below screen the first line indicates the current selected laser state of the EDFA If you want to select a different st...

Page 16: ...cally stops From the below screen the first line indicates the current selected buzzer state of the EDFA If you want to select a state different from your current buzzer state using the Up or Down swi...

Page 17: ...EDFA output power monitoring The Output Power is displayed the EDFA output power of several ports The LD Bias Current is the bias current of the pump laser diode The unit of LD Bias Current is mA The...

Page 18: ...e temperature state of the EDFA module OK Normal FAIL Abnormal Shows the input optical signal power of the EDFA OK Normal FAIL Abnormal Shows the output optical power of the EDFA OK Normal FAIL Abnorm...

Page 19: ...ate of the Buzzer can be checked 4 2 6 Function Setting The Function Setting menu is Time The timer setting procedure for the internal timer is as follows In the below screen the Current Time indicate...

Page 20: ...ed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 20 If you push the Enter switch the time value is stored 4 2 7 IPAddress The IP Address menu is showed IP Address of network YYY...

Page 21: ...lay basic hardware information on EDFA cls Clear the console screen ping Check connection of equipment to which an IP address is assigned logout Log out from ADMIN or USER account Not available for Te...

Page 22: ...0 1 icmp_seq 1 ttl 64 time 0 9 ms 64 bytes from 192 168 0 1 icmp_seq 2 ttl 64 time 0 9 ms 64 bytes from 192 168 0 1 icmp_seq 3 ttl 64 time 0 9 ms 192 168 0 1 ping statistics 4 packets transmitted 4 p...

Page 23: ...14 digits to input the time information such as YYYYMMDDhhmmss ex MPU SET TIME 20061207091830 MPU GET SYSINFO View MPU Model Name Description Serial Number Firmware Version Hardware Version ex ADMIN...

Page 24: ...V 240V PS output voltage 5 1 V Alarm enable value bit F SHELF GET ALARM All alarm status of shelf system 1 value is OK Another value is Not OK ex ADMIN shelf get alarm Now All alarm value of SHELF sys...

Page 25: ...67c2 05 08 060f2b06010401ba291402060104030300 02010c Pwr Supply1 alarm occurred index 4 4f806b10 05 08 060f2b06010401ba291402060104030300 02010c Pwr Supply1 alarm occurred index 5 4f806c37 05 08 060f2...

Page 26: ...LOP Alarm Threshold ARG3 set opmode Card index 1 ref Card index 1 losth lopth hihi value 0 ARG4 set opmode Value 20 AGC or 30 APC ref Value Reference value 10 losrh lopth hi value 0 ARG5 set losrh lo...

Page 27: ...m OPM alarm threshold value information ALARM HIHI 24 0 dBm ALARM HI 23 0 dBm ALARM LO 10 0 dBm ALARM LOLO 9 0 dBm BIAS and TEMP alarm threshold value information of LD LD NO 1 BIAS ALARM HIHI 700 mA...

Page 28: ...ble trapcomm Trap Community ver Version Select admintype ADMIN authentication Type SNMP V3 usertype USER authentication Type SNMP V3 adminkey ADMIN account MD5 SHA Key userkey USER account MD5 SHA Key...

Page 29: ...N OFF ex ADMIN snmp set trapen 1 on snmp setting is Successful SNMP SET TRAP Index IP Address Ex ADMIN snmp set trap 1 92 168 0 31 snmp setting is Successful This setting will be applied after reboot...

Page 30: ...lifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 30 ADMIN ntp set server 141 223 182 106 172 0 0 1 NTP Server Setting is Successful NTP GET SERVER ADMIN ntp get server server 141 223 182 106...

Page 31: ...255 0 Gateway 192 168 0 1 5 1 3 SNMP Configuration This unit supports SNMPv1 SNMPv2 and SNMPv2c SNMPv3 will not be supported until next software upgrades Using MIB Table for SNMP interface GUI Graphi...

Page 32: ...identifier RO alarmEnable 1 3 6 1 4 1 5591 1 1 1 1 2 x octets RO currentAlarmState 1 3 6 1 4 1 5591 1 1 1 1 3 x Integer32 RO analogAlarmHIHI 1 3 6 1 4 1 5591 1 1 1 1 4 x Integer32 RO analogAlarmHI 1...

Page 33: ...larmLogNumberOfEntry 1 3 6 1 4 1 5591 1 2 1 0 Integer32 RO alarmLogLastIndex 1 3 6 1 4 1 5591 1 2 2 0 Integer32 RO alarmLogIndex 1 3 6 1 4 1 5591 1 2 3 1 1 x Integer32 RO alarmLogInformation 1 3 6 1 4...

Page 34: ...lticastAddressIndex 1 3 6 1 4 1 5591 1 3 3 2 1 1 x Integer32 RO commonMulticastAddressNumber 1 3 6 1 4 1 5591 1 3 3 2 1 2 x Octets R W commonMaxMulticastAddress Maximum number of multicast address com...

Page 35: ...RO heCommonLogOID 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 2 x Object Identifier RO heCommonLogValue 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 3 x Integer32 RO heCommonLogState 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3...

Page 36: ...1 2 1 3 1 x Integer32 RO heFanUnitAlarm status of fan 1 is ok another value is not ok heFanStatusIndex index of fan heFanStatusAlarm status of fan 1 is ok another value is not ok x FAN Index 1 2 5 2 1...

Page 37: ...r both ADMIN and USER accounts In addition the task of administrative work such as network connection monitor and control of EDFA can be performed under the ADMIN account The USER account holder usual...

Page 38: ...naged Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 38 5 3 2 Monitoring The present status of the optical amplifier can be monitored Status data can be automatically refreshed a...

Page 39: ...14 39 5 3 3 Parameter The parameter page provides a view similar to the screen shot below The Input Power and Output Power alarm threshold values are displayed and can be modified Other elements are r...

Page 40: ...5 www dktcomega com mail dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 40 5 3 4 Control set This page allows for various control settings to be adj...

Page 41: ...m Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 41 5 3 5 Event log The Event Log page will display all of the recorded events during the optical amplifier s oper...

Page 42: ...Manual Rev 1 3 OFA CCS CCD Series June 2014 42 5 3 6 IP Login set IP Subnet mask and Gateway addresses can be set via this page Passwords for Admin and User accounts can be set A system reboot and Fac...

Page 43: ...Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 43 5 3 7 SNMP set SNMP Trap IP addresses can be set and enabled disabled The Trap community information is case sensitive and shou...

Page 44: ...tcomega com mail dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 44 5 3 8 Manual The user s manual in PDF format is resident on the amplifier and ava...

Page 45: ...the front panel All the LED s on the front panel turn on The LCD on the front panel shows the Start state When the Start state of LCD ends all the LED s on the front panel turn off and the related LED...

Page 46: ...ate and the optical input power condition is within the optical input power range of the EDFA check the optical output power of the EDFA 6 4 Alarm Test The LOS Alarm of the Shelf Type EDFA occurs when...

Page 47: ...The optical input power of the EDFA does not meet the minimum requirement 3 Green Red The optical output power of the EDFA does not meet the specified output power 4 Green Yellow The bias current of...

Page 48: ...5 www dktcomega com mail dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 48 If you identify the problems as shown in the Table or have an unidentifie...

Reviews: