![DKT Comega OFA-CCD series User Manual Download Page 24](http://html1.mh-extra.com/html/dkt-comega/ofa-ccd-series/ofa-ccd-series_user-manual_2512812024.webp)
DKT A/S
Fanoevej 6
DK-4060 Kirke Saaby
Tlf
Fax
E-mail
Web
+45 4646 2626
+45 4646 2625
www.dktcomega.com
Network Managed Optical Amplifier
User’s Manual Rev 1.3
OFA-CCS/CCD Series
June 2014
24
SHELF GET INFO : View Logical ID
SHELF GET PSINFO : Power supply module information
ex)
ADMIN:> shelf get psinfo
--------------------------------------------------------
# Power Supply Voltage Information.
Power supply module count : [2]
Power supply No.[1] type : DC -48
PS output voltage : 1.3[V]
Alarm enable value(bit) : [F]
Power supply No.[2] type : AC 100V ~ 240V
PS output voltage : 5.1[V]
Alarm enable value(bit) : [F]
--------------------------------------------------------
SHELF GET ALARM : All alarm status of shelf system
‘
1
’
value is OK. Another value is Not OK.
ex)
ADMIN:> shelf get alarm
--------------------------------------------------------
# Now, All alarm value of SHELF system. #
* FAN status alarm *
No.1 : [1]
No.2 : [1]
Value '1' is OK. Value '2' is FAIL.
* Power supply status alarm *
No.1 : [5]
No.2 : [1]
Value '1' is OK. Another Value is FAIL.
* Key Als Status *
Laser status : [2]
Value '1' : Laser On, Value '2' : Laser Off.
* Casetemp status alarm : [1].
Value '1' is OK. Another Value is FAIL.
* Optical component status alarm *
IPM status alarm : [5]
OPM status alarm : [5]
* LD component status alarm *
LD No.1
BIAS alarm : [1]
TEMP alarm : [1]
LD No.2
BIAS alarm : [1]
TEMP alarm : [1]
LD No.3
BIAS alarm : [1]
TEMP alarm : [1]
LD No.4
BIAS alarm : [1]