PR95 Operator’s Manual
Prepare - 35
Prepare Jobsite
CMW
Dig Launch and Burster Pits
Dimensions
Requirements
Exit Pit (1)
•
Must be in line with existing pipe.
•
Sloped back end aids new pipe entry.
Burster Pit (2)
•
Must be in line with existing pipe.
•
Must allow burster to be level with existing pipe.
Unit
Burster Pit
Exit Pit *
Length (A)
Width (B)
Length (C)
Width (D)
U.S. (metric)
U.S. (metric)
U.S. (metric)
U.S. (metric)
PR95
12’ (3.6 m)
5’ (1.5 m)
10’ (3 m)
3’ (1 m)
* Exit pit dimensions depend on pipe depth and product being installed.