![Ditch Witch JT5 Operator'S Manual Download Page 36](http://html1.mh-extra.com/html/ditch-witch/jt5/jt5_operators-manual_2510009036.webp)
JT5 Operator’s Manual
Controls - 35
ESID
CMW
®
2.
Strike indicator
Red lights come on as values
in display increase.
Light in triangle represents
strike warning condition and
will trigger alarm(s) and
strobe(s).
Remember that system can
go from one or two lights to
an electric strike immediately.
NOTICE:
The ESID does not indicate
proximity to electric lines. System will
activate only when voltage and/or
amperage detected at the drilling unit
are above threshold minimum limits.
3.
Alarm interrupt button
To turn off strike alarm at
drilling unit, press.
4.
Voltage problem
indicator
Blinking red light indicates a
voltage indicator problem.
See “ESID Diagnostic Codes” on
page 91.
5.
Current problem
indicator
Blinking red light indicates a
current indicator problem.
See “ESID Diagnostic Codes” on
page 91.
Item
Description
Notes
Summary of Contents for JT5
Page 1: ...JT5 Issue 3 0 Original Instruction Operator s Manual CMW 053 2380...
Page 7: ...Overview 6 JT5 Operator s Manual CMW...
Page 21: ...Safety 20 JT5 Operator s Manual Machine Safety Alerts CMW...
Page 61: ...Drive 60 JT5 Operator s Manual Shut Down Unit CMW...
Page 85: ...Conduct a Bore 84 JT5 Operator s Manual Remove Pullback Device CMW...
Page 119: ...Complete the Job 118 JT5 Operator s Manual Stow Tools CMW...
Page 149: ...Specifications 148 JT5 Operator s Manual CMW...
Page 152: ......
Page 153: ......
Page 154: ...JT5 Operator s Manual Service Record 153 CMW Service Record Service Performed Date Hours...
Page 155: ...CMW Service Record 154 JT5 Operator s Manual Service Performed Date Hours...