![Ditch Witch JT40 Operator'S Manual Download Page 215](http://html.mh-extra.com/html/ditch-witch/jt40/jt40_operators-manual_2510008215.webp)
Service - 214
JT40/JT40 All Terrain Operator’s Manual
50 Hour
50 Hour
Drilling Unit
Change Fluid Pump Oil (Initial Service)
Change fluid pump oil at first 50 hours and every
2000 hours thereafter.
To change:
1.
Drain at plug (3). Ensure that magnetic drain
plug is cleaned of debris before reinstalling.
2.
Add 2.8 qt (2.6 L) MPL at fill plug (2). Maintain
fluid level at sight glass (1).
Location
Task
Notes
DRILLING
UNIT
Change fluid pump oil
Initial service, MPL
Check radiator
Change hydraulic filters
Initial service
Check ground drive gearbox oil level
2 gearboxes, MPL
Check rotation gearbox oil level
MPL
Inspect thrust rollers
Drain water from hydraulic tank
Check heavy duty anchor gearbox oil level
MPL
Check SaverLok inner drive collar
AT only
Check SaverLok
®
torque
DOWNHOLE
TOOL
Rebuild AT Rockmaster
®
housing
AT only; kit available
1
2
3
j59om092w.eps
Summary of Contents for JT40
Page 1: ...JT40 JT40 All Terrain HRC and LRC Issue 1 0 Original Instruction Operator s Manual 053 2966 ...
Page 79: ...Controls 78 JT40 JT40 All Terrain Operator s Manual Battery Disconnect ...
Page 113: ...Drive 112 JT40 JT40 All Terrain Operator s Manual Shut Down Unit ...
Page 119: ...Transport 118 JT40 JT40 All Terrain Operator s Manual Retrieve ...
Page 147: ...Conduct a Bore 146 JT40 JT40 All Terrain Operator s Manual Remove Pullback Device ...
Page 199: ...Complete the Job 198 JT40 JT40 All Terrain Operator s Manual Stow Tools ...
Page 241: ...Service 240 JT40 JT40 All Terrain Operator s Manual As Needed ...
Page 250: ......
Page 251: ......
Page 253: ...Service Record 252 JT40 JT40 All Terrain Operator s Manual Service Performed Date Hours ...