35
5.2.3.
Special instructions for winter use
The lowest allowed operating temperature of the lift is -20 °C
In cold conditions, carry out the following special actions in addition to the normal start-up
procedure:
1. Let the power pack run for a few minutes before starting the movements.
2.
To ensure the proper operation of the valves, do first a few warm-up movements to
change warm oil in the cylinders.
3. Check that the limit switches and the emergency descent devices are operational and
clean (from dirt, snow, ice, etc.).
4. Protect the control centre and the platform from snow and ice whenever they are not in
use.
Always keep the lift free from dirt, snow etc.
5.2.4.
Ending the work
At the end of the workday:
1. Retract the telescopic boom fully.
2. Lower the boom/platform onto the support on the tow-bar. The limit switch on the
transport support prevents the operation of the support outriggers if the platform is not
down.
3. Close the control centre cover on the work platform.
4. Turn the selector switch to position OFF, and turn off the main switch.
5. Disconnect the lift from the power supply.
6. Always take the selector switch key with you, when you leave the lift.
7. Make sure that the covers are locked.
Summary of Contents for 10196
Page 2: ......
Page 3: ...3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS Valid from serial number 105TL 10196...
Page 6: ...6 Operating instructions DINO 105TL BLANK...
Page 10: ...10 Operating instructions DINO 105TL 2 1 DIMENSION DRAWING...
Page 46: ...46 Operating instructions DINO 105TL NOTES...
Page 47: ...47 NOTES...
Page 51: ...51 7 2 LUBRICATION PLAN 5 8 6 10 7 5 4 2 1 11 3 9 12...
Page 55: ...55 BLANK...
Page 56: ...56 Operating instructions DINO 105TL BLANK...
Page 58: ...58 Operating instructions DINO 105TL NOTES...
Page 59: ...59 NOTES...