23
6. Safety devices for hose rupture
All the load-bearing cylinders are equipped with valves for rupture or leak in the hydraulic
system, which prevent the load from falling.
Outrigger cylinders
Lock valves
Prevent the inching of the
outriggers in either direction.
Lifting cylinder of the boom
Load regulation valve
Prevents the load from falling
Telescope cylinder
Load regulation valve
Prevents the inching of the
telescope in either direction.
Levelling system
Load-holding valves
Prevents the inclination of the
platform in either direction.
7. Emergency stop buttons
Depressing the emergency stop button, stops all the movements immediately and turns off
the power unit. The button can be found at each control station. Once the button has been
depressed, only the emergency descent functions remain operational.
The emergency stop button locks in the lower position, and it must be released before
starting the power unit.
DANGER
WARNING
CAUTION
NOTICE
If the unit does not start, make sure that the emergency descent button is not in the lower
position at any of the control stations.
Summary of Contents for 10196
Page 2: ......
Page 3: ...3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS Valid from serial number 105TL 10196...
Page 6: ...6 Operating instructions DINO 105TL BLANK...
Page 10: ...10 Operating instructions DINO 105TL 2 1 DIMENSION DRAWING...
Page 46: ...46 Operating instructions DINO 105TL NOTES...
Page 47: ...47 NOTES...
Page 51: ...51 7 2 LUBRICATION PLAN 5 8 6 10 7 5 4 2 1 11 3 9 12...
Page 55: ...55 BLANK...
Page 56: ...56 Operating instructions DINO 105TL BLANK...
Page 58: ...58 Operating instructions DINO 105TL NOTES...
Page 59: ...59 NOTES...