4
©
Dinel, s.r.o. CLM–36
3 . f
eatures
of
variants
CLM –36_–10
With uncoated rod electrode
for level measurement of non-conductive
liquids (oils, diesel, petrol) and powder or bulk-solid materials (flour, sand,
cement, plastic granulates, etc.). Max. length 5 m.
CLM –36_–11
With fully (PFA) coated rod electrode
for level measurement of water and
conductive liquids incl. wasted liquids in metallic vessels, concrete sumps,
reservoirs, etc., better behaviour against aggressive media, lower adhesion
to some complicated media, chemical resistance. Max. length 3 m.
CLM –36_–12
With fully (FEP) coated rod electrode
for level measurement of water and
conductive liquids incl. wasted liquids in metallic vessels, concrete sumps,
reservoirs, etc., better behaviour against aggressive media, lower adhesion
to some complicated media, chemical resistance. Max. length 3 m.
CLM –36_–20
With uncoated rod electrode and reference tube
for accurate level meas-
urement of clean non-conductive liquids (oils, diesel, petrol). By means of
reference tube the output signal does not depend on the dimensions and
shapes of a vessel. Max. length 3 m.
CLM –36_–22
With fully FEP coated rod electrode and reference tube
for accurate level
measurement of conductive liquids. Main use is for measurement in plastic
vessels or tanks. Impossible to use for waste and high viscosity liquids and
bulk-solid materials. Max. length 3 m.
CLM –36_–30
With uncoated stainless steel rope electrode and uncoated weight
for level measurement of bulk-solid materials (grains, sand, flour, cement,
etc.). Max. length 20 m.
CLM –36_–31
With uncoated stainless steel rope electrode and coated dynamic
anchorage
for level measurement of bulk-solid materials in higher silos.
Max. length 20 m.
CLM –36_–32
With fully coated rope electrode and coated weight
(rope insulation FEP,
weight insulation PTFE), for level measurement of electrically conductive
and non-conductive liquids. Max. length 20 m.
CLM –36_–40
With two coated electrodes
(rode insulation FEP, head fully PTFE), for
level measurement of aggressive liquids. Performance for non-explosive
areas only. Max. length 2 m.
Summary of Contents for CLM-36
Page 2: ......
Page 27: ...26 Dinel s r o CLM 36...