CLM–36
©
Dinel, s.r.o.
23
t
m –
Medium operating
temperature
t
p –
Temperature
in process connection place
t
a
– Ambient temperature range
(on housing)
N, Xi variants
NT, XiT variants
p
ressure
durability
Variants / Performance
Maximal operation pressure for temp
erature
t
p
to 30°C
to 85°C
to 130°C
to 160°C
to 200°C
CLM –36N–10, 20
7 MPa
5 MPa
–
–
–
CLM –36N–11, 12, 22
4 MPa
2 MPa
–
–
–
CLM–36N–30
7 MPa
5 MPa
–
–
–
CLM –36N–31
–
–
–
–
–
CLM –36N–32
1 MPa
0,5 MPa
–
–
–
CLM –36N–40
0,1 MPa
0,1 MPa
–
–
–
CLM –36Xi–10, 20
7 MPa
5 MPa
–
–
–
CLM –36Xi–11, 12, 22
4 MPa
2 MPa
–
–
–
CLM–36Xi–30
7 MPa
5 MPa
–
–
–
CLM –36Xi–31
–
–
–
–
–
CLM –36Xi–32
1 MPa
0,5 MPa
–
–
–
CLM –36NT–10, 20
7 MPa
5 MPa
3 MPa
2 MPa
1 MPa
CLM –36NT–11, 12, 22
6 MPa
4 MPa
2 MPa
1,5 MPa
0,3 MPa
CLM –36NT–30
7 MPa
5 MPa
3 MPa
–
–
CLM –36NT–31
–
–
–
–
–
CLM –36NT–32
1 MPa
0,5 MPa
0,1 MPa
–
–
CLM –36XiT–10, 20
7 MPa
5 MPa
3 MPa
2 MPa
1 MPa
CLM –36XiT–11, 12, 22
6 MPa
4 MPa
2 MPa
1,5 MPa
0,3 MPa
CLM –36XiT–30
7 MPa
5 MPa
3 MPa
–
–
CLM –36XiT–31
–
–
–
–
–
CLM –36XiT–32
1 MPa
0,5 MPa
0,1 MPa
–
–
Fig. 16: Points for temperature determination on the level meter