20
©
Dinel, s.r.o. CLM–36
17 . s
pecification
t
echnical
specification
(variants N, NT)
Supply voltage
CLM – 36N(T)–_ _–_–I
CLM – 36N(T)–_ _–
_–U
9 ... 36 V DC
16 ... 36 V DC
Current output
Voltage output
4 ... 20 mA
0 ... 10 V
Power consumption (off-load) CLM–36N(T)–_ _–
_–U
approx. 8mA
Sensitivity ranges
20 ; 30 ; 50 ; 100 ; 150 ;
300 ; 500 ; 1000 pF
Initial capacity regulation ratio
min. 1:2
Nonlinearity
max. 1 %
Temperature error
max. 0,05% / K
Voltage error for current and voltage output
max. 0,3
μ
A/V and 0,1 mV/V
Internal resistance / Electric strength (Electrode – Housing)
1 M
Ω
/ 250 V AC
Coupling capacity / Electric strength (Housing – Supply leads)
51 nF / 250 V AC
Protection
class
Standard
Optional (Connector GAN-DADE 7A / DAEE 7A)
IP67 (Housing), IP65 (Connector)
IP67
Maximal load (serial) resistance for current output
(U = 24 V)
R
max
= 750
Ω
Minimal load resistance for voltage output
R
min
> 1 k
Ω
Maximum tensile strength of the rope electrode
1400 kg
Recommended cable
PVC 2x0,75 mm
2
(3x0,5 mm
2
)
Weight (exclude electrode)
Version N, Xi
Version NT, XiT
approx. 0,5 kg
approx. 1 kg
e
lectrical
paraMeters
(variants Xi, XiT)
Supply voltage
9 ... 30 V DC
Max. internal values
Ui = 30 V DC; Ii = 132 mA;
Pi = 0,99 W; Ci = 370 nF;
Li = 0,9 mH
Internal resistance / Electric strength (Electrode – Housing)
1 M
Ω
/ 250 V AC
Coupling capacity / Electric strength (Housing – Supply leads)
26 nF / 500 V AC
Allowed temperature range in zone 0 (EN
50284)
-20 ... +60°C
Allowed pressure range in zone 0 (EN 50284)
0,08 ... 0,11 MPa
p
rocess
connection
Type
Size
Marking
Metric thread
M36 x 2
M
Pipe thread (except CLM–36–40)
G 1"
G
Pipe thread for CLM–36–40)
G 1½"
G
Tri-clamp (standards DN 20)
–
Cl