Instruction Manual
SAFELINE VARIO Diagnostics
33
2 Rack-Diagnostics
2.10. Status information about module RMV
Status information RMV
Slot
Slot number
The box will be checked if the following conditions are met.
SK1 - SK4
Conditions for safety circuit 1 ... safety circuit 4 are met.
ZH
Conditions for two-hand control are met.
Relais 1
Relay 1 has attracted
Relais 2
Relay 2 has attracted
2.11.
Status information about network module NIV
Status information NIV
Slot
Slot number
Network address
Specifies the address of the NIV module, whose data are presented here.
The box will be checked if the following conditions are met.
SK1 - SK4
Conditions for safety circuit 1 ... safety circuit 4 are met.
RTNI
Specifies whether the signal RTNI was set.
IN1…IN8
shows the state of the inputs of this NIV module. The first digit indicates
the network address from where the signals were sent.
OUT1…OUT8
shows the state of the outputs of this NIV module. The first digit indicates
the network address to which the signals were sent.