Instruction Manual
SAFELINE VARIO Diagnostics
13
2 Rack-Diagnostics
2.3.1.
Overview of possible representation types of modules
No error
Module ok
A red highlighted central module signals a SLOK-OFF State, i.e. a faulty
operating state. In this connection, the slot number under the module is
red highlighted and the A1 terminal is shown in orange.
SLOK-OFF always requires a restart of the central module.
If only the slot number is red highlighted and the corresponding module
yellow, it indi-cates a plausibility error, however, does not necessarily lead
to a SLOK-OFF state. Error information of the modules can be accessed
by clicking on the red slot number. These errors are then displayed with
an error number and a brief description.
The module number is highlighted with a blue outline of the selected
diagnostic modules. In case a module number is not outlined means
this module is not selected for the diagnostics. For these modules, the
associated diagnostic information is not updated.
Modules that are configured in the application, but not present
in the rack as hardware (muting), are shown in gray.