Instruction Manual
SAFELINE VARIO Diagnostics
31
2 Rack-Diagnostics
In the latch window of the designer there are more possibilities for error listed. They refer mainly
to internal hardware error, that lead to the shutdown of the operation system:
IPK error
IPK data error
CAN error
Port error
5V error
Checksum error
To delete / acknowledge these error messages the icon RTSK
has to be wired.
2.7.
Status information about Fieldbus Module FBV
Status information FBV
With the buttons IN / OUT- 1 and IN / OUT- 2 the section of fieldbus inputs and outputs
FBI / O1-8 or FBI / O9-16 are selected.
• The bits of FBIx correspond to the FB inputs FBIx.1-FBIx.8 in the logic diagram.
• The bits of FBOX meet the FB outputs FBOx.1-FBOx.8 in the logic diagram.
With the buttons LZ Oct x, you see the content of the bytes from the FB-RT-Diag
(see Designer manual).
Slot
slot number
Adr
station address
In the left pane, the following states are displayed.
The boxes are checked, if the conditions are met.
SK1 - SK4
Conditions for safety circuit 1 ... safety circuit 4 are met.
ZH
Conditions for two-hand control are met.
RTFB
Fieldbus outputs are activated.