Product Information
Safety technics modular generation in metal housing version 08 dated: 2009-04-10 page 24 from 32
Use of inputs E1, E2,Q
The inputs E1, E2 and Q can be used as inputs for an emergency shutdown button.
If this functionality is not used, the inputs Q, E1 and E2 must be connected permanently to 24 VDC. This can best
be done with short wire bridges between the input terminals and the terminals A1.
Function diagram
External triggering
u / n
u / n max.
t
UB
33-34, 43-44
57-58, 67-68
E2
E1
Q
Verzögerungszeit
Delay time
Temps de retard
Verzögerungszeit
Delay time
Temps de retard
E1
E2
E2
E1
Q
DNDS VMG: Time delay Table
S1 function
Channel 1
position 1-3
S1 function
Channel 2
position 4-6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
on
1
2
3
4
5
6
Standard
0s
0,5s
1,0s
2,0s
5,0s
10,0s
15,0s
20,0s
10VG00-02
0s
0,1s
0,5s
1,0s
2,0s
5,0s
10,0s
20,0s
Bus card adjustment. Adjusted by DINA
SPEED1
1.
Überwachung
Monitoring
Surveillance
8.
Überwachung
Monitoring
Surveillance
33
34
43
44
24
23
14
13
STOP
2.
3.
4.
5.
6.
7.
DNDS VMG
Buskarte
Bus card
O-P-V
4
3
2
1
o
n
5
6
G-1SP
G-2SP
SPEED2
57
58
67
68
DNDS VMG: Faults and Errors
•
The second output contact can not be switched on when the other output contact is welded.
•
LED “SPEED” and “STOP” on the monitoring and output module do not illuminate.
Reason:
The encoder is not connected.
•
Proximity sensor failure.
•
The LED STOP and SPEED on the output module flash: short illuminated, long not illuminated.
Reason:
A contact does not close or open or
The time adjustment of the output module differs between channel1 and channel2.