EN-12
451903.66.17 · FD 9908
www.gdts.one
English
LWP 200E
12 Technical data
1
Type and order code
LWP 200E
2
Design
2.1
Defrosting
No
2.2
Nominal cylinder volume
litre
200
2.3
Transfer area of the internal heat exchanger
m
2
-
2.4
Sensor pipe ø
internal
for external sensors
mm
-
2.5
Installation location
Frost-free
2.6
Cylinder material
Enamelled steel complying with DIN 4753
2.7
Cylinder insulation
PU with foil cladding
2.8
Nominal cylinder pressure
bar
10
3
Operating limits
3.1
Heat source operating limit
°C
15 to 35
3.2
Domestic hot water setting range in heat pump operation
°C
23 to 60
± 1.0 K
4
Flow / sound
4.1
Air flow level I II III
m
3
/h
60, 90, 140
4.2
External compression, level III
Pa
120
4.3
Sound power level I / II / III
dB(A)
46.7 / 54.4 / 64.5
4.4
Sound pressure level I / II / III
1
dB(A)
1. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
36.8 / 45.3 / 55.9
5
Dimension/weight and filling quantities
5.1
Dimensions height (max.) x cross-section (max.)
mm
1700 x 550
5.2
Air duct connection diameter
mm
125
5.3
Weight (empty)
kg
85
5.4
Refrigerant R 134a/total filling weight
(kg)
1.0
5.5
GWP value / CO
2
equivalent
--- / t
1430 / 1
5.6
Refrigeration circuit hermetically sealed
yes
6
Electrical connection
6.1
Degree of protection
IP 21
6.2
Connection voltage
1/N/PE~230 V, 50 Hz
6.3
Connecting cable approx. 2.7 m - 1.5 mm
2
With plug
6.4
Fuse max.
A
C16
6.5
Power consumption heat pump cos
A
0.8
6.6
Supplementary electrical heating power consumption
A
6.5
6.7
Power consumption max.
A
8.7
6.8
Heat pump nominal power consumption at 45 °C
2
W
2. Air intake temperature of 20 °C and relat. humidity of 70 %
253
6.9
Supplementary electrical heating power consumption
W
1500
6.10 Total power consumption max.
W
1900
7
Hydraulic connection
7.1
Circulation pipe connection
external thread
-
7.2
Domestic hot water outlet connection
external thread
R 3/4“
7.3
Cold water inlet connection
external thread
R 3/4“
7.4
Internal heat exchanger connection
external thread
-
8
Performance values
8.1
Heating-up period from 15 °C to 45 °C
h
7.6
8.2
Mean heat output at 45 °C
W
910
8.3
COP (t) complying with EN 255 at 45 °C
3.4
8.4
Stand loss in 24h
3
W
3. Room temperature 20 °C (heat pump operation)
1.13