Page 31
Section 9: System Health checks
The following items should be verified to ensure
efficient operation of the system:
Heat pump
Check the fan is clear from debris.
No abnormal sound during operation.
Electrical
Power cable is firmly fixed.
Earth wire connection is secure.
RCCB operation is normal.
Supply voltage is correct.
Hydraulic
Water pressure higher than 0.05 MPa.
Pressure relief valve operation is normal.
The filter is clear of debris.
Check entire system for leaks.
Cylinder
Set temperature is correct for efficient
operation.
Check the high temperature cut out stat on
the cylinder immersion and buffer immersion
have not tripped.
Temperature and pressure relief is operating
correctly.
For full maintenance details for the cylinder consult the
relevant instruction manual.
Wall mounted thermostat
Every 2 years, replace the battery on the
Horstmann PRT1
Heating operation normal.
The set temperatures and heating periods are
suitable for the tenants life style.
Heat pump controller
LCD control panel operation is normal.
Enquire if the user is warm enough and
reduce the weather compensation curve to
maximise the heat pump efficiency.
Section 10: Standard packages
To assist with the design and installation of a system
Dimplex have collated wiring and hydraulic schematics
for the following designs:
Package 1 and 2
Heating and Domestic hot water preparation is done
using the heat pump.
2 x two port valves are used to switch between
heating and DHW preparation.
Room temperature is time and temperature
controlled using the Horstmann wall mounted
thermostat. The thermostat will create a demand if
the temperature drops below 15
C whilst the system
is off to prevent the base temperature dropping too
low.
DHW temperature and time period is set using the
Heat pump controller.
Package 3
Package for space heating only so no hot water
cylinder is included.
Buffer cylinder is required to ensure minimum
water volume.
Room temperature is time and temperature
controlled using the Horstmann wall mounted
thermostat. The thermostat will create a demand if
the temperature drops below 15
C whilst the
system is off to prevent the base temperature
dropping too low.
Never use cleaning agents containing sand,
soda, acid or chloride as these can damage
the surfaces.
Before opening the device, ensure that all
circuits are isolated from the power supply.
Any work on the heat pump may only be
performed by authorised and qualified after-
sales service technicians.
Summary of Contents for LA 12 MI
Page 35: ...Page 34 Package 1 and 2 Plumbing Schematic...
Page 36: ......
Page 40: ...Page 39 CE declaration of conformity...
Page 41: ...Page 40 LA 6 MI performance...
Page 42: ...Page 41 LA 6 MI continued...
Page 43: ...Page 42 LA 9 MI performance...
Page 44: ...Page 43 LA 9 MI performance continued...
Page 45: ...Page 44 LA 12 MI performance...
Page 46: ...Page 45 LA 12 MI performance continued...
Page 47: ...Page 46 LA 16 MI performance...
Page 48: ...Page 47 LA 16 MI performance continued...
Page 49: ...Page 48 Product Dimensions LA 6 MI and LA 9 MI...
Page 50: ...Page 49 Product Dimensions LA 12 MI and LA 16 MI...
Page 61: ...Page 60 Information for DHW cylinder with buffer ECS125HP 580...
Page 62: ...Page 61 Information for DHW cylinder with buffer ECS150HP 75 580...
Page 63: ...Page 62 Information for DHW cylinder with buffer ECS210HP 75 580...