Page 7
An inverter compressor starts gently ramping up to its
maximum speed over a couple of minutes meaning the
current increase is very gradual. The fixed speed
compressor has a larger starting current because it
doesn‟t turn on gradually. The starting current is smoothed
by an inbuilt soft-starter to keep it within acceptable limits.
The starting current does not cause any problems
because an in-built randomised time delay that ensures
multiple heat pumps to not turn on at the same time.
An inverter heat pump is able to modulate down its output
as the external temperature increases. A fixed speed heat
pump will run at a constant speed meaning that its output
increases with rising temperature. This means that an
inverter compressor could achieve slightly higher cylinder
temperatures for the same size coil although in practice
both types of compressor can achieve suitable cylinder
temperatures.
Advantages of fixed speed compressors
A fixed speed compressor is designed to work at the
optimum performance level all of the time. An inverter
compressor does not always work in the optimum zone
because it modulates its output to match the heat demand.
The „over
-
driving‟ of an inverter compressor causes it
efficiency to drop.
Since the output of both the fixed and inverter
compressors drop with decreasing temperature, there
becomes a point when a secondary heat source is
required to match the properties heat demand, known as
the Bivalent point. At lower temperatures an inverter
compressor and a fixed speed compressor are equally as
efficient despite the inverter needing more immersion
support.
Heat pump labelling
The product code for the inverter range of heat pumps
continues the same convention as the rest of Dimplex‟s
heat pump range.
Letter Meaning
L
Luft (German for air)
A
Aus (German for outside)
##
Nominal kW rating
M
Mono (German for single phase)
I
Inverter
Table 1: Product coding convention
Comparison of the LA MS and LA MI ranges
The LA MI and LA MS range of heat pumps are ideal for
providing DHW and space heating. In addition, the MS
range of heat pumps also has a sophisticated controller
capable of controlling more complicated systems.
MI range
MS range
Compressor speed
Variable
Fixed
Heating only
Heating & DHW
Mixed heating circuits
Swimming pool
Solar Thermal
Boiler integration
Multiple heat pump
Table 2: Comparison of WPM and MI Range
Summary of Contents for LA 12 MI
Page 35: ...Page 34 Package 1 and 2 Plumbing Schematic...
Page 36: ......
Page 40: ...Page 39 CE declaration of conformity...
Page 41: ...Page 40 LA 6 MI performance...
Page 42: ...Page 41 LA 6 MI continued...
Page 43: ...Page 42 LA 9 MI performance...
Page 44: ...Page 43 LA 9 MI performance continued...
Page 45: ...Page 44 LA 12 MI performance...
Page 46: ...Page 45 LA 12 MI performance continued...
Page 47: ...Page 46 LA 16 MI performance...
Page 48: ...Page 47 LA 16 MI performance continued...
Page 49: ...Page 48 Product Dimensions LA 6 MI and LA 9 MI...
Page 50: ...Page 49 Product Dimensions LA 12 MI and LA 16 MI...
Page 61: ...Page 60 Information for DHW cylinder with buffer ECS125HP 580...
Page 62: ...Page 61 Information for DHW cylinder with buffer ECS150HP 75 580...
Page 63: ...Page 62 Information for DHW cylinder with buffer ECS210HP 75 580...