48
•
If the Primer Cup is not centered in the Platform and Shellplate hole--Realign the Primer Slide.
10.2
Adjusting The Primer Drop Alignment
10.2.1
Make sure there are no primers in the Magazine Tube and the Operating Handle is up. Remove the Magazine
tube. Shine a small flashlight in the opening as shown below and look down the Shield Tube and verify the
Primer Hole in the Primer Slide is centered directly under the opening in the Primer Feed body as shown below.
If not, adjust the Primer Slide Stop on the back of the RL550C in or out no more than 1/8 of a turn at a time, to
fine-tune the position of the Primer Slide. See the graphical depiction below. Reinstall the Primer Magazine.
Primer Cup must enter and be
centered in the Hole in
Platform and Shellplate
without dragging
Shine Flashlight
here and look
down Primer
Shield Tube
Flashlight
View down inside Primer Shield
Tube—Cup centered in hole in
Primer Feed Body
Primer Drop -Cup
Position Set
Screw –adjust
in/out to align
Cup to Magazine
Primer Slide forward
travel adjustment Screw
and Locknut
WARNING! -Wear
Safety Glasses
Summary of Contents for RL550C
Page 44: ...44 9 4 Powder Measure Conversion refer to the Exploded View below ...
Page 60: ...60 15 RL550C EXPLODED VIEWS AND PARTS IDENTIFIER 15 1 Complete Assembly Exploded View 1 ...
Page 61: ...61 15 2 Frame and Lower Assembly Exploded View 2 ...
Page 62: ...62 15 3 Toolhead Assembly Exploded View 3 ...
Page 63: ...63 15 4 Platform and Components Exploded View 4 ...
Page 64: ...64 15 5 Primer Feed Assembly PN 20263 no Operating Rod Exploded View 5 ...
Page 65: ...65 15 6 Powder Measure Assembly ...
Page 66: ...66 15 7 Primer Early Warning System PN20302 Rod and PEWS Kit PN14497 PEWS Alone ...
Page 75: ...75 18 RL550C TEMPLATE FOR DRILLING MOUNTING HOLES IN BENCH ...