Digital Projection
E-Vision 6500 Series
A Tour Of The Menus
Operating Guide
Page 35
Rev D July 2014
Signal menu
Horizontal and Vertical Position, Phase, Clock
•
Adjust the sliders for these settings, as required.
Reset
•
Press
ENTER
to restore the four settings above their factory defaults.
•
When the warning message appears, use
or
to move the green highlight to
YES
or
NO
, then press
ENTER
to confirm your selection.
Resolution
•
Set this to
Auto
, unless the projector has problems selecting between
Wide
and
4:3
with
some signals on the Computer 1, Computer 2 and Component inputs.
Auto Sync
•
Set this to
On
if you want the projector to automatically synchronise with the input signal.
•
Set this to
Off
if the settings are to be made manually, using the sliders above only.
Notes
See also
Using the Menus
, earlier
in this guide and
Menu Map
, later in
this guide.
These settings are used for VGA
signals only.
Do NOT do this unless you are
sure that you want to restore the
settings to their factory defaults.
The
Resolution
setting is needed
only for VESA 1024x768_ 60,
VESA 1280x768_60,
VESA 1400x1050_60 and
VESA 1680x1050_60 signals on
the Computer 1, Computer 2 and
Component inputs.
The
Auto Sync
setting is used for
VGA signals only.