System Specifications
Storage
Specifications
Table C–4 lists the environmental specifications for the
VAXstation 4000 system.
Table C–4 System Storage Specifications
Temperature range
5°C to 50°C (41°F to 122°F)
Relative humidity
10% to 95% (noncondensing)
Altitude
0 to 2400 m (0 to 8000 ft)
Maximum wet bulb temperature
32°C (90°F)
Minimum dew point
2°C (36°F)
Operating
Conditions
Table C–5 lists the operating conditions for the VAXstation 4000
system.
Table C–5 VAXstation 4000 Operating Conditions
Temperature range
15°C to 32°C (59°F to 90°F)
Temperature change rate
11°C/hr (52°F/hr) maximum
Relative humidity
20%–80% (noncondensing)
Altitude
2400 m (8000 ft)
Maximum wet bulb temperature
28°C (82°F)
Minimum dew point
2°C (36°F)
Nonoperating
Conditions
Table C–6 lists the nonoperating conditions for the VAXstation
4000 system.
Table C–6 VAXstation 4000 Nonoperating Conditions
Temperature range
–40°C to 66°C (–40°F to 151°F)
Relative humidity
95% @ 66°C (151°F) (may
condense)
Altitude
4900 m (16,000 ft)
Maximum wet bulb temperature
28°C (82°F)
Minimum dew point
2°C (36°F)
C–4 Model 90 System Specifications