10) Parameter of soft limit function (9 in total)
#374
enable Soft Limit
0
BOOL
1/0
0:Disable, 1:Enable
#375
value X-- Soft Limit
-400
BOOL
-2000~0
#376
value Y-- Soft Limit
-400
BOOL
-2000~0
BOOL
-2000~0
#377
value Z-- Soft Limit
-400
#378
value A-- Soft Limit
-400
BOOL
BOOL
-2000~0
#379
value X++ Soft Limit
400
0~2000
BOOL
0~2000
#380
value Y++ Soft Limit
400
BOOL
0~2000
400
BOOL
0~2000
400
#381
value Z++ Soft Limit
#382
value A++ Soft Limit
8) Parameter of Probe function (8 in total)
9) Parameter of hard limit function(16 in total)
#68
1
BOOL
1/0
0
:
disable 1
:
enable
#69
20
mm
0~200
#70
0
BOOL
1/0
1: High; 0:Low active
#71
0
BOOL
1/0
0: current position; 1:fixed position mode
#72
#73
#74
#75
enable Probe
thickness of tool sensor
level of probe signal
initial tool's position
initial X axis in fixed mode
initial Y axis in fixed mode
initial Z axis in fixed mode
Back off distance after probing
0
0
0
10
mm
mm
mm
mm
0-9999
0-9999
0-9999
0~200
#400
enable X-- limit
1
BOOL
1/0
0
:
Disable 1
:
Enable
#401
enable Y-- limit
1
BOOL
1/0
0
:
Disable 1
:
Enable
#402
Enable Z-- limit
1
BOOL
BOOL
1/0
1/0
0
:
Disable 1
:
Enable
0
:
Disable 1
:
Enable
#403
enable A-- limit
1
BOOL
1/0
0
:
Disable 1
:
Enable
1
BOOL
1/0
0
:
Disable 1
:
Enable
1
BOOL
1/0
0
:
Disable 1
:
Enable
1
BOOL
1/0
0
:
Disable 1
:
Enable
1
BOOL
1/0
0
#404
enable X++ limit
#405
enable Y++ limit
#406
enable Z++ limit
#407
enable A++ limit
#408
active level X-- limit
1: High; 0:Low
BOOL
1/0
0
1: High; 0:Low
BOOL
1/0
0
1: High; 0:Low
BOOL
1/0
0
1: High; 0:Low
BOOL
1/0
0
1: High; 0:Low
BOOL
1/0
1: High; 0:Low
#409
active level Y-- limit
#410
active level Z-- limit
#411
active level A-- limit
#412
active level X++ limit
#413
active level Y++ limit
0
BOOL
1/0
1: High; 0:Low
0
BOOL
1/0
1: High; 0:Low
0
#414
active level Z++ limit
#415
active level A++ limit
Tools position X coordinate in the
Mach(ine) coordinate system
Tools position Y coordinate in the
Mach(ine) coordinate system
The set value will trigger the limit signal.
The limit values refer to the machine
coordinates, not the work piece coordi-
nate.
The set value will trigger the limit signal.
The limit values refer to the machine
coordinates, not the work piece coordi-
nate.
Height of Z axis before the XY move
under the Mach(ine) coordinate system
Para.
Mark
Parameter definition Default
value
Parameter
Unit
Parameter
Scope
Notes
Para.
Mark
Parameter definition Default
value
Parameter
Unit
Parameter
Scope
Notes
Para.
Mark
Parameter definition Default
value
Parameter
Unit
Parameter
Scope
Notes