Laser Ally Speed LIDAR Operator Guide
28
Digital Ally, Inc.|Doc. 30157 Rev 12
To measure the average speed of additional vehicles, simply click the
trigger once to clear the old reading and timer is re-armed for a new
reading.
Load Defaults
The factory default settings for the LIDAR can be restored at any
time by pressing
then selecting “Load Defaults” using the
up/down arrows
and pressing Enter
. This
command restores default brightness and audio levels as well as
settings for Minimum and Maximum range values.
ECCM Control
The ECCM menu allows the operator to temporally disable the
LIDAR’s Electronic Counter-Counter Measure (anti-jamming) system.
To activate or disable the ECCM, press
then use the up/down
arrows
to select “ECCM” and press
. Then use
the up/down arrows to select “Active” or “Disabled” and press
to confirm your selection. If ECCM is disabled, the LIDAR unit
will return to ECCM “Active” if it is not in use for a few hours, if the
batteries are replaced, or if “Load Defaults” is selected.
Note: While the Laser Ally is fully functional with ECCM set to
“Disabled”, the ECCM setting should be left in the “Active” state
during normal operation to give the full protection against laser
detectors and jammers.