30
7.2 Defects and possible causes
Defect
Posible cause
Action
·
CATRAX Plus will not
tun on
·
The power supply cable is not connected
properly
·
The fuse of the power supply is blown
·
Check the cables and the
fuse (fuse: 3 A)
·
CATRAX Plus locked
·
Optical sensors obstructed or defective
·
Perform the preventive
routine maintenance on the
sensors or forward the
equipment to the Technical
Assistance
·
A CATRAX Plus does
not activate the
electromagnet
(turnstile cannot be
locked)
·
The cable is broken or the distance
between the electromagnet and the
locking device is maladjusted
·
Adjust the electromagnet or
forward the equipment to the
Technical Assistance
·
The arm does not
remain in the correct
position
·
There is wear, dirt, a broken spring or
lack of lubrication in the sphere base
·
Request a replacement for
the faulty part or forward the
equipment to the Technical
Assistance
·
CATRAX Fit does not
lock in the first tooth
·
The distance between the electromagnet
and the locking device is maladjusted
·
Adjust the electromagnet or
forward the equipment to the
Technical Assistance
plus