17
Sensors:
The sensors must connect the sensor's input to the counter's ground wire (switches,
optical couplers, buttons, relays, etc.).
Power characteristics:
POWER
2 batteries AA (3V)
5V (battery eliminator)
BATTERY LIFE
1,5 ano ou mais de 3.000.000 de cycles(alkaline batteries, with
sensors and open buttons)
NUMBER OF DIGITS
6
PERIOD OF DATA RETENTION
1 min 30 secs (to replace batteries without losing count)
DIGITS SIZE
8 x 4 mm (height x width)
6.3 Power supply
This power supply was especially designed for the CATRAX
. Among the main
line
advantages of this optional item, is its adaptation capability to the voltage variations
often found in installation sites – the input voltage can vary between 100 and 240 Vca.
The supply's specific technical features, protections and dimensions were carefully
tested and approved in hostile temperature and environmental conditions, which
ensures the adequate power supply to the equipment's performance. Besides the input
and output voltages indicated in the image below, the supply has a short-circuit and
overheating protection.
INPUT:
100 A 240 Vca
OUTPUT:
Ground wire
Neutral
Phase
12V 5% / 3A
+-
GND
TIP:
The power supply can be mounted to the board's support that
accompanies
.
CATRAX Plus
plus