10
5.2 Floor drilling
Before installing
, check:
CATRAX Plus
1. The place chosen for the installation.
2. If there is a power source or electric socket nearby (ducts for connection).
3. If the place chosen is adequate for the installation of the access controller (indoors).
4. If there will be enough space (minimum 5 cm) between the rear of the CATRAX Plus
column and the wall. This space is important in order to provide access to the upper
panel and plug's locks for the cables passage.
5. If there will be enough space for the arms after CATRAX Plus is assembled.
6. If the floor is in conditions to receive anchor bolts (minimum of 4 cm of FCK15 M.P.A.
concrete or equivalent).
5.3 Column fixation
To fixate the column to the floor, observe the following steps and the indicated images:
1. drill the floor with 3/8” drills (then use a 12mm or the ½” drill). Make four external
holes, according to the measures indicated in the image below:
ATENTION:
Since the
installation requires floor drilling, it is
CATRAX Plus
important that the location be chosen carefully.
plus
INFORMATION:
The measures presented in this manual are in millimeters
and inches.
12,5 (4x)
210
(8,267")
170
(6,692")
78
(3,070")
36
(1,417")
Saída de cabos
92,5
(3,641")
32
(1,259")
20
(0,787")
Furação
de fixação
51
(2,007")
79,5
(3,129")
160
(6,299")