6.4 Control board
CATRAX Plus's control board was designed to meet most technologies of access control
terminals in the market. The controller have mechanical features and layout perfectly
suited for the CATRAX Plus's needs and it is one of the best options for the equipment's
operation.
The following image shows the control board with its straps, connectors, and dipswitch,
as well as the location of the power supply and the control board.
The table below describes the functions of the control board's connectors:
plus
Cn1
Cn2
Ds1
Cn8
Sinal
Nome/Descrição
CN1
INPUTS
1
(+) vext1 (enables turn through voltage)
2
HAB1 (from right to left)
3
GND
4
Vext2 (enables turn through voltage)
5
HAB2 (enables turn through dry contact – from left to right)
6
GND
7
(+) 12Vcc (available to auxiliary – maximum 500 mA)
8
CLOCK1 (input for reader from left to right)
9
DATA1 (input for reader from left to right)
10
CLOCK2 (input for reader from right to left)
11
DATA2 (input for reader from right to left)
12
GND
CN2
OUTPUTS
1
NO or NC Contact (HAB1 return)
2
Contact C (HAB1 return)
3
NO or NC Contact (HAB2 return)
4
Contact C (HAB2 return)
5
Output for indicative X (open collector NPN – maximum 500 mA) orange w ire Output
6
Output for arrow < (open collector NPN – maximum 500 mA) green w ire
7
for arrow > (open collector NPN – maximum 500 mA) blue w ire
8
(+) 24Vcc (indicative arrow s’ pow er) red w ire
9
GND (indicative arrow s’ pow er) black w ire
10
(+) solenoid of badge collector box
11
(-)solenoid of badge collector box
12
Sound signal (open collector – NPN)
CN3
POWER - POWER INPUT
1 Power input +12Vca
2 Power input GND
3 GND