AT commands
I/O settings commands
Digi XBee® 3 802.15.4 RF Module User Guide
156
Parameter range
0, 1, 4, 5
Parameter
Description
0
Disabled
1
SPI_ATTN
2
N/A
3
N/A
4
Digital output, low
5
Digital output, high
Default
1
I/O settings commands
The following commands configure the various I/O lines available on the XBee 3 802.15.4 RF Module.
D0 (DIO0/ADC0/Commissioning Configuration)
Sets or displays the DIO0/ADC0/CB configuration (TH pin 20/SMT pin 33).
Parameter range
0 - 5
Parameter
Description
0
Disabled
1
Commissioning Pushbutton
2
ADC
3
Digital input
4
Digital output, low
5
Digital output, high
Default
1
CB (Commissioning Button)
Use
CB
to simulate Commissioning Pushbutton presses in software.
You can enable a physical commissioning pushbutton with
.