DSI SPCI Network Interface Boards Programmer's Manual Issue 5
81
Description:
This message is issued by s7_mgt on completion of the initial configuration
sequence and indicates either success (status=zero) or an error condition
that occurred during configuration. The message is only issued when s7_mgt
is run with the
–i
command line option specifying the module_id of the
Notification Module
to which the message is sent. For example:
s7_mgt
–i0x2d
Note:
It is recommended that the user invoke this option and then wait for the
API_MSG_CNF_IND message to ensure the application does not attempt to send
messages until initial configuration is complete.
Parameter Description:
Completion Status
The result of initial configuration coded as follows:
Value
Meaning
0 Success
1
Error opening config.txt file
2
Syntax or value error in config.txt file
3
Error during configuration (invalid parameters)
4
Error during configuration (no response)
6.4.3
Clock Event Indication
Synopsis:
Message issued by the board to indicate on-board clocking related events.
Message Format:
MESSAGE HEADER
Field Name
Meaning
type MVD_MSG_CLK_IND
(0x0e23)
id
0
src MVD_TASK_ID
dst
0xdf
rsp_req
0
hclass
0
status Event
ID
(see below)
err_info
Reserved for future use
len
0