6 Message Reference
70
Message Format:
MESSAGE HEADER
Field Name
Meaning
type
MVD_MSG_SC_CONNECT
(0x7e1f)
id 0
src
Sending Module ID
dst
MVD_TASK_ID
(0x10)
rsp_req
used to request a confirmation
hclass 0
status
Status Response
(if confirmation requested)
err_info 0
len 16
PARAMETER AREA
Offset Size
Name
0 2 local_stream
2 2 local_slot
4 2 mode
6 2 source_stream
8 2 source_slot
10 2
dest_stream
12 2
dest_slot
14 2
pattern
Description:
This message is sent to the DSI SPCI Board to control the CT bus switch.
Several different actions can be performed depending on the value of the
mode
parameter, these are CT bus to local bus connection, local bus to CT
bus connection, duplex connection between CT bus, and local bus and duplex
connection between local bus timeslots.
The confirmation message (if requested) indicates success by status of zero.
Parameter Description:
The following table depicts which parameters are required for each of the
seven different modes. (* = parameter is required)