Dialogic SCbus Linecard Installation and Replacement
R3B
ã
Aug 2001 Ericsson Enterprise AB
23
17. At the Dialogic Configuration Manager – Add Hardware Wizard dialog box, select
the Family of the Dialogic linecard.
If the Dialogic linecard you are
adding is a…
Then…
D/41ESC
Select
D/x1E
in the Family box.
D/160SC-LS
Select
DIALOG/HD
in the Family box.
18. Select the model of Dialogic card in the Model box, then click
Next
.
19. When prompted to name the linecard, type the linecard identification number into the
box, then click
OK
.
20. At the Dialogic Configuration Manager Properties dialog box, click the
System
tab.
21. From the Parameter list, select
BLTId
(for Board Locator Technology Identification).
22. From the Value list, select the BLTId according to Table 6.
Table 6. BLTId Numbers
Linecard Switch
SW1 BLTId
1 0
0x00
2 1
0x01
3 2
0x02
4 3
0x03
5 4
0x04
6 5
0x05
7 6
0x06
8 7
0x07
9 8
0x08
10 9 0x09
11 A
0x0A
12 B
0x0B
13 C
0x0C
14 D
0x0D
15 E
0x0E
16 F 0x0F
23. From the Parameter list, select
BLTAddress
.
24. From the Value list, select
D0000
.